FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

DOOR ADJUSTMENT

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Check the doors to make sure they have an equal gap between them and that the vertical edge of the door is parallel to the vertical door seal. If the doors are not positioned in this manner, adjust the doors as described.

2.Remove the top front cover.

3.Loosen the screws that secure the upper door bearings and related hardware, just enough to allow door movement.

4.Move the door until proper alignment is achieved then tighten the screws on the upper door bearing hardware.

5.Repeat step 3 and 4 on the opposite door, if necessary.

DOOR CATCH BALL

ADJUSTMENT

(INDEPENDENT DOORS)

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Remove top front cover as outline under COVERS AND PANELS in REMOVAL AND REPLACEMENT OF PARTS.

2.Open the doors and inspect door strike for proper shape.

A.Replace if bent and adjust as outlined in this procedure.

3.Open and close the doors several times while observing the catch ball operation.

A.Replace if malfunctioning and adjust as outlined in this procedure.

NOTE: Shims may be required under the door strike, before the proper door tension adjustment can be set.

F32700 (February 2006)

 

Page 24 of 64

 

Page 24
Image 24
Wolf WKGDX 126624, WKGX 126623, WKGC 126622, WKGCX 126625 Door Adjustment, Door Catch Ball Adjustment Independent Doors