Wolf WKGCX 126625, WKGDX 126624, WKGX 126623, WKGC 126622 GAS Orifice, GAS Solenoid Valve

Models: WKGX 126623 WKGD 126621 WKGCX 126625 WKG 126620 WKGC 126622 WKGDX 126624

1 64
Download 64 pages 8.19 Kb
Page 9
Image 9

FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS

6.Reverse procedure to install the replacement burner.

NOTE: Ensure that burner positioning bracket (U shaped end) is inserted into slot at the rear of the burner chamber.

7. Check for proper operation.

GAS ORIFICE

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS BEFORE SERVICING THE UNIT.

1.Remove the bottom front cover as outlined under

COVERS AND PANELS.

2.Remove the bolts securing the gas manifold to the oven and place the manifold to the side.

4.Reverse procedure to install and check for proper operation.

GAS SOLENOID VALVE

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS BEFORE SERVICING THE UNIT.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH A SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the control panel and the right side panel as outlined under COVERS AND PANELS.

NOTE: If right side panel is not accessible, this component can be serviced by removing the control panel as outlined under COVERS AND PANELS.

2.Disconnect the lead wires.

3.Disconnect the compression fittings to the valve.

3.Remove the gas orifice from the spud on the manifold and replace with the correct orifice for the given altitude.

Page 9 of 64

 

F32700 (February 2006)

 

Page 9
Image 9
Wolf WKGCX 126625, WKGDX 126624, WKGX 126623, WKGC 126622, WKGD 126621, WKG 126620 GAS Orifice, GAS Solenoid Valve