FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS

6.Remove the nuts that secure the motor mounting plate to the rear wall.

7.Place a piece of cardboard on the bottom of the oven cavity to protect its surface from any damage during motor assembly removal.

8.Pull the motor assembly into the oven cavity and place it on the cardboard.

9.Remove the junction box cover from the motor, disconnect lead wires and remove the conduit.

10.Remove motor mounting bolts and flat washers then lift the motor from the mounting plate.

11.Position the replacement motor on the motor mounting plate and install mounting bolts and washers. Hand tighten mounting bolts only.

12.Reconnect lead wires at the motor, replace conduit and junction box cover.

NOTE: Check data plate on motor for wiring schematic. The motor must rotate clockwise when viewed from the shaft end.

13.Slide blower onto motor shaft until hub is flush with end of shaft then tighten set screws.

14.Adjust motor position until blower is parallel to motor mounting plate as outlined under BLOWER ADJUSTMENT in SERVICE PROCEDURES AND ADJUSTMENTS.

15.Position motor mounting plate on the rear wall and secure with nuts and washers.

16.Replace the baffle panel and SNORKEL.

17.Replace the air baffle on the rear wall at the lower right hand corner.

18.Remove cardboard from the bottom of the oven cavity.

19.Install rack guides and racks.

20.Check oven for proper operation.

OVEN DOORS AND BEARINGS

(INDEPENDENT DOORS)

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Remove the top front cover and bottom front cover as outlined under COVERS AND PANELS.

F32700 (February 2006)

 

Page 12 of 64

 

Page 12
Image 12
Wolf WKGDX 126624, WKGX 126623, WKGC 126622, WKGCX 126625, WKGD 126621, WKG 126620 Oven Doors and Bearings Independent Doors