Wolf WKGCX 126625 Computer Control Calibration WKGC/WKGCX, Probe Test, Solid State Relay Test

Models: WKGX 126623 WKGD 126621 WKGCX 126625 WKG 126620 WKGC 126622 WKGDX 126624

1 64
Download 64 pages 8.19 Kb
Page 27
Image 27

FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

 

ALTERNATING ON

MENU

DISPLAY

 

 

PARAMETER

 

DATA

 

 

 

 

Celsius_Fahrenheit

C_F

 

F

 

 

 

 

Guard Band

gb

 

4000

 

 

 

 

Temperature

tcnP

 

OFF

Compensation

 

 

 

 

Input Type 1

InP1

 

J

 

 

 

 

Range Low 1

rL1

 

75

 

 

 

 

Range High 1

rH1

 

500

 

 

 

 

Hysteresis

HYS1

 

3

 

 

 

 

Calibration Offset

CAL1

 

0

 

 

 

Exit Setup Mode and

set point temperature is

displayed or if call for

return to Operation

heat, dashes (----)

 

Mode.

 

displayed.

 

 

 

Probe Test

1.Set the control to 350EF.

2.Access the back of the control panel to disconnect the probe lead wires.

3.Install a jumper wire across the probe terminals. This will simulate room temperature.

A.If the heat light comes on and the actual temperature is room temperature, replace the probe.

B.If the heat light does not come on or the actual temperature is not room temperature, replace the control.

Solid State Relay Test

1.Remove the right side panel as outlined under

COVERS AND PANELS.

2.Set the temperature to 350°F or high enough to keep the heat ON for several minutes.

3.Check for +5 VDC on input side of SSR (terminals 3 & 4).

A.If +5 VDC is present, continue to step 4.

B.If no voltage is present, computer control is not functioning properly.

4.Check for 120 VAC at load side of SSR (terminals 1 & 2).

A.If no voltage is present, solid state relay is not functioning properly.

1)Replace the SSR and check for proper operation.

B.If 120 VAC is present, component is functioning properly.

5.Re-assemble oven and check for proper operation.

COMPUTER CONTROL

CALIBRATION

(WKGC/WKGCX)

1.Place a thermocouple in the geometric center of the oven cavity.

2.Set the ON-OFF-OVEN COOL switch to ON.

A.If the set point temperature is 350°F, proceed to step 4.

B.If the set point temperature is other than 350°F, proceed to step 3 to change the temperature.

3.Press the set key then temperature key to enter the temperature set mode.

A.The display will alternate between the term StPt (set point) and the current oven temperature setting.

B.Press the up or down arrow keys to make the proper selection.

C.Press the set key again to save the change and exit the temperature set mode.

4.Allow the oven temperature to stabilize (normally 3 cycles).

5.Compare the controls set point temperature to the thermocouple meter reading when the heat light goes out.

A.A temperature variance more than 5°F indicates an adjustment is needed.

1)To make the adjustment, proceed to step 6.

2)If temperature variance is less than 5°F, computer control is functioning properly.

6.Enter the setup mode as outlined in SETUP MODE under COMPUTER CONTROL (WKGC/WKGCX).

A.Advance through the menu until CAL1 (Calibration Offset) appears.

1)If the thermocouple reading is higher than set point temperature, press the down arrow key and enter a negative offset value that is equal to the number of degrees above the 5°F tolerance.

Page 27 of 64

 

F32700 (February 2006)

 

Page 27
Image 27