FULL SIZE GAS CONVECTION OVENS - ELECTRICAL OPERATION

 

 

trial cycle repeats after a 15

 

E.

Power switch (S1) OFF.

 

 

second purge between

 

F.

Function switch (S3) set to Normal ROAST

 

 

cycles for two additional

 

 

 

 

 

cycle.

 

 

tries before locking out. To

 

 

 

 

 

G.

Oven light switch (S2) ON/OFF (position

 

 

reset after a lockout, turn

 

 

 

power switch (S1) OFF then

 

 

has no affect on the function of the Normal

 

 

ON.

 

 

ROAST cycle).

5. Oven reaches the fixed HOLD temperature and

 

H.

Temperature control dial set to lowest

 

the hold thermostat opens.

 

 

temperature (fully counterclockwise).

 

A. Heat light goes out.

 

I. High limit switch CLOSED.

 

B. Power removed from heat relay (R3) and

 

J. Roast timer (normal cooking) in the OFF

 

 

the contacts open (N.O.).

 

 

position.

 

 

1) Ignition control module de-energized.

 

K. Roast and Hold timer in the OFF position.

 

 

a. Power removed from 2nd valve

 

L.

Oven doors Closed.

 

 

(main) on the gas valve and gas

 

 

1) Door switch contacts CLOSED.

 

 

flow to the burner stops.

 

 

 

 

 

M.

Oven cavity temperature below 140°F.

 

C. Power is also removed from motor speed

 

 

2.

Set temperature control dial to desired ROAST

 

 

relay (R1).

 

 

1) Convection fan motor de-energized

 

then HOLD temperature (Roast & Hold

 

 

 

cooking).

 

 

and fan stops rotating.

 

 

 

3.

Power switch (S1) turned ON.

6.

The oven will continue to cycle on the hold

 

A.

Component cooling fan energized.

 

thermostat until the ROAST & HOLD timer is

 

 

turned to the OFF position, the function switch

 

B.

Power ON light (Amber) comes ON.

 

(S3) is changed back to ROAST (normal

 

 

 

C.

Power to one side of the following

 

cooking) or the power switch (S1) is turned to

 

 

the OFF or OVEN COOL position.

 

 

components: Normal ROAST timer

WKGD, WKGDX With Roast & Hold Option (Solid

 

 

terminal 1, ROAST & HOLD timer terminal

 

 

1, transformer primary (T1).

State Temperature Control)

 

 

 

NOTE: Power is available to the oven light

Schematic diagram 10834 will be used to explain the

 

 

switch (wire #20) to turn the oven cavity lights

electrical sequence of operation for both the Normal

 

 

ON when the light switch is turned ON; and

ROAST cycle (normal cooking) and the ROAST &

 

 

power is available to the normally open N.O.

HOLD cycle.

 

 

side (wire #28) of the door switch contacts and

 

 

 

 

 

Normal Roast Cycle

 

connects power to additional components when

1.

Conditions.

 

the door switch contacts are CLOSED (door

 

closed).

 

A.

Oven connected to correct voltage.

 

 

 

 

1) Transformer (T1) energized.

 

 

1) L1 (HOT) to power switch (S1).

 

 

 

 

 

 

a. Power (24VAC) to one side of

 

 

 

 

 

 

 

 

2) L2 (NEUTRAL or SECOND LINE) to

 

 

the following components: heat

 

 

one side of the following components:

 

 

relay (R3) normally open (N.O.)

 

 

power ON light, heat light,

 

 

contacts, high limit --- connected

 

 

temperature control board terminal 9

 

 

through the normally closed

 

 

(120VAC) or terminal 10 (208-

 

 

(N.C.) contacts to the 1st valve

 

 

240VAC), oven cavity lights, buzzer,

 

 

(safety) on the dual solenoid gas

 

 

ROAST timer motor (normal cooking),

 

 

valve.

 

 

ROAST & HOLD timer motor, heat

 

 

a) 1st valve (safety) on the gas

 

 

relay coil (R3), convection fan motor

 

 

valve energized.

 

 

common (C), transformer primary

 

 

 

 

 

 

NOTE: Gas does not flow to the

 

 

(T1), motor speed (Hi/Low) relay coil

 

 

 

 

(R1), hold relay coil (R2) and the

 

 

burner until the 2nd valve (main)

 

 

component cooling fan.

 

 

is energized.

 

B.

Oven properly grounded.

 

 

2) With door switch closed, power is

 

C.

Gas supply valve ON.

 

 

applied to motor speed (Hi/Low) relay

 

 

 

(R1) normally open (N.O.) contacts

 

 

 

 

 

 

 

D. Gas combination control valve ON.

 

 

and hold relay (R2) common (C).

 

 

 