Wolf WKGCX 126625, WKGDX 126624, WKGX 126623, WKGC 126622 GAS Pressure Adjustment, Temp F Ohms

Models: WKGX 126623 WKGD 126621 WKGCX 126625 WKG 126620 WKGC 126622 WKGDX 126624

1 64
Download 64 pages 8.19 Kb
Page 21
Image 21

FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

5.Reverse procedure to install.

TEMP (°F)

OHMS*

TEMP (°F)

OHMS*

77

90000

360

822

 

 

 

 

240

4077

380

656

 

 

 

 

260

3016

400

529

 

 

 

 

280

2266

425

424

 

 

 

 

300

1726

450

334

 

 

 

 

320

1332

475

266

 

 

 

 

340

1041

 

 

 

 

 

 

(*) Resistance in ohms ± 10%

GAS PRESSURE ADJUSTMENT

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

4.Remove adjustment screw cap from the gas valve and turn gas supply to the oven back on.

5.Plug the unit in and turn the power switch ON.

6.Set the temperature control to its highest setting and allow burner to ignite.

WARNING: SHUT OFF THE GAS BEFORE SERVICING THE UNIT.

1.Remove the right side panel as outlined under COVERS AND PANELS in REMOVAL AND REPLACEMENT OF PARTS.

NOTE: If right side panel is not accessible, this component can be serviced by removing the control panel as outlined under COVERS AND PANELS.

2.Remove the plug from the manifold pressure port.

NOTE: Accurate gas pressure adjustments can only be made with the gas on and the burner lit.

7.Turn the set screw to obtain the proper gas pressure (clockwise = pressure increase; counterclockwise = pressure decrease).

 

PRESSURE READINGS (IN W.C.)

 

 

 

 

 

GAS

MANIFOLD

LINE

 

 

TYPE

RECOMMENDED

MIN

MAX

 

 

 

 

 

 

 

 

Natural

3.5

7

5

14

 

 

 

 

Propane

10

11

11

 

NOTE: If the incoming line pressure to the valve is less than the minimum stated, then the manifold pressure can not be set correctly.

3.Install hose barb adapter and attach manometer tube.

Page 21 of 64

 

F32700 (February 2006)

 

Page 21
Image 21
Wolf WKGCX 126625, WKGDX 126624, WKGX 126623, WKGC 126622, WKGD 126621, WKG 126620 GAS Pressure Adjustment, Temp F Ohms