FULL SIZE GAS CONVECTION OVENS - TROUBLESHOOTING

SYMPTOMS

 

POSSIBLE CAUSES

Normal (Roast) mode OK, no Hold mode.

1.

Roast and Hold switch (S3) malfunction.

(Roast & Hold models only).

2.

R2 hold relay malfunction.

 

3.

Roast & Hold timer malfunction.

 

4.

Interconnecting wiring malfunction.

 

 

 

Component cooling Fan does not run.

1.

Motor inoperable.

 

2.

Interconnecting wiring malfunction.

 

 

 

Uneven Cooking.

1.

Convection Fan motor speed/direction.

 

2.

Poor combustion.

 

 

A. Gas pressure incorrect.

 

 

B. Exhaust vent plugged or obstructed.

 

 

C. Snorkel Vent plugged or obstructed.

 

3.

Air flow Baffles missing or damaged.

 

 

 

Intermittent problems.

1.

High ambient temperatures.

 

2.

Wiring connections loose.

 

3.

Cooling fan malfunction.

 

 

 

No power to temperature control.

1.

Power switch (S1) in OVEN COOL.

 

2.

Door or door switch open.

COMPUTER CONTROL MODELS ONLY

SYMPTOM

 

POSSIBLE CAUSES

Oven does not heat.

1.

High limit switch open.

 

2.

Probe malfunction.

 

3.

Control malfunction.

High limit thermostat shutting off gas

1.

Probe malfunction.

burner.

2.

Control malfunction.

Oven not hot enough.

1.

Probe malfunction.

 

2.

Control range high (rH1) setting to low. See SETUP MODE

 

 

under COMPUTER CONTROL (WKGC, WKGCX).

 

3.

Control malfunction.

Error Codes

In the display window, the error code will alternate between the code and the oven cavity temperature or dashes if the oven is calling for heat (heat light on). When the condition causing the error is resolved, normal oven operation can resume.

NOTE: To check a SETUP PARAMETER and its corresponding DATA VALUE, see SETUP MODE under

COMPUTER CONTROL (WKGC/WKGCX).

NOTE: If the cause of the error is not apparent, check for these conditions as they may also cause errors to occur: Electrical noise or a noise event, excess environmental moisture or temperature, or vibration.

CODE & PROBLEM

PROBABLE CAUSE

SOLUTION

Er01 - ROM checksum error

Internal ROM malfunction

Cycle power

 

 

 

Er02 - RAM checksum error

Internal RAM malfunction

Cycle power

 

 

 

Er03 - Ambient sensor error

Ambient temperature is below 32EF

Check ambient temperature at the

 

 

control.

Er04 - Configuration error

Microprocessor malfunction

Cycle power

 

 

 

Er05 - EEprom error

Power loss while storing data

Cycle power

Page 63 of 64

 

F32700 (February 2006)

 

Page 63
Image 63
Wolf WKGCX 126625, WKGDX 126624, WKGX 126623, WKGC 126622, WKGD 126621, WKG 126620 Computer Control Models only, Error Codes