FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS

TEMPERATURE PROBE

(WKGD/WKGDX)

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Remove the right side panel as outlined under

COVERS AND PANELS.

NOTE: If right side panel is not accessible, this component can be serviced by removing the control panel as outlined under COVERS AND PANELS.

2.Disconnect the probe leads from the temperature control.

3.Remove the racks and right rack support.

4.Remove probe clips from probe.

5.Push the probe through the opening in cavity side wall and into the control panel area.

NOTE: The hole in the oven cavity wall does not line up straight with the oven cavity outer shell, therefore the probe must be removed at an angle.

6.Reverse the procedure to install the replacement probe.

7.Adjust the temperature control as outlined under

SOLID STATE TEMPERATURE CONTROL CALIBRATION (WKGD/WKGDX) in SERVICE PROCEDURES AND ADJUSTMENTS.

GAS BURNER

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS BEFORE SERVICING THE UNIT.

1.Remove the lower front cover as outlined under

COVERS AND PANELS.

2.Disconnect the ignition cable and the flame sense lead wire.

3.Remove the bolts securing the gas manifold and place manifold aside.

4.Remove the screws securing the burner cover then lift out.

5.Grasp the burner and lift out.