FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS

2. Remove the door switch lever.

8.Reverse procedure to install door assembly and check for proper adjustment as outlined under DOOR ADJUSTMENT and DOOR SWITCH ADJUSTMENT in SERVICE PROCEDURES AND ADJUSTMENTS.

OVEN DOORS

(SIMULTANEOUS DOORS)

Assembly Removal

3.Remove the lower door seal strip to expose the mounting screws of the door assembly.

4.Remove the two (2) lower sill bolts by the lower door shaft and the four (4) counter-sunk screws from the lower sill.

NOTE: The door assembly is heavy and will drop down once the last screw is removed. If removing door assembly with-out assistance, the ignition cable, flame sense lead and gas manifold should also be removed to avoid damage to these components.

5.Tilt the top of the door slightly forward and lift the door up until the bottom of the door shaft clears the opening in the sill.

6.Lay the door flat to prevent damage.

7.The top and bottom bearings are now accessible for inspection and/or replacement if needed.

A.If bearings are ok, proceed to step 8.

B.If replacing the top bearing, remove the top bearing retainer and top bearing.

C.If replacing the bottom bearing, remove it from the door shaft or the lower sill opening.

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Remove the top front cover and bottom front cover as outlined under COVERS AND PANELS.

2.Remove the door switch lever.

3.Remove the top bearing retainers and top bearings.

4.Remove the lower door seal strip to expose the mounting screws of the door assembly.

A.Remove the two (2) lower sill bolts by the lower door shaft and the four (4) counter-sunk screws from the lower sill.

Page 13 of 64

 

F32700 (February 2006)

 

Page 13
Image 13
Wolf WKGX 126623, WKGDX 126624, WKGC 126622, WKGCX 126625, WKGD 126621 Oven Doors Simultaneous Doors, Assembly Removal