F.The stop cable must be positioned where it moves freely and does not get pinched.

3.Position door chain assembly to factory setting if the conditions in step 2 are not met.

4.If right door does not lead the left door in closing:

A.Loosen locknut on both turnbuckles.

B.Loosen left turnbuckle.

C.Tighten right turnbuckle.

D.Tighten locknut on both turnbuckles.

5.If the right door leads the left door by more than 3/8 inch:

A.Loosen locknut on both turnbuckles.

B.Loosen right turnbuckle.

C.Tighten left turnbuckle.

D.Tighten locknut on both turnbuckles.

6.Check doors for proper operation.

NOTE: The locknuts must be tight during testing or the adjustment will not hold.

A.If doors do not close properly, repeat step 4, 5 and 6.

B.If doors operate properly, continue with procedure.

7.Install the lower front cover.

COMPUTER CONTROL

(WKGC/WKGCX)

Operation

Refer to the Owner's Manual for specific operating instructions.

Setup Mode

NOTE: Use the setup mode to verify that the control is configured to the factory settings which result in the proper operation of the oven. If the CAL1 parameter is other than zero, determine if it is still needed before resetting to zero. See COMPUTER CONTROL CALIBRATION (WKGC/WKGCX).

CAUTION: Changing the C_F, InP1, rL1 & rH1 parameters will default all menus.

1.Use this key sequence to access the setup mode.

Up arrow; Rack 1; Temperature; Temperature; Down arrow; Rack 1

2.Once in the setup mode the display will alternate between the parameter and programmed data.

To change data to the factory setting, use the arrow keys.

To select the next parameter, press the Rack 1 key.

After the last Parameter and Data is viewed, press the Rack 1 key a final time to exit the setup mode and return to operations mode. The current set point temperature will be displayed.

After 1 minute of no key activations, the control will return to operation mode.

3.Listed are the parameters and data you should find.