FULL SIZE GAS CONVECTION OVENS - ELECTRICAL OPERATION
2. Power Switch (S1) turned to OVEN COOL. |
|
| a. Power (24VAC) to one side of | ||||
NOTE: With door switch contacts OPEN (doors |
|
| the following components: heat | ||||
|
| relay (R3) normally open (N.O.) | |||||
open), the convection fan motor will still run and |
|
| |||||
|
| contacts, high limit | |||||
continue to cool the oven. However, power would be |
|
| |||||
|
| through the normally closed | |||||
removed from the following components: Power ON |
|
| |||||
|
| (N.C.) contacts to the 1st valve | |||||
light (goes out), Normal ROAST timer, ROAST & |
|
| (safety) on the dual solenoid gas | ||||
HOLD timer, transformer T1 |
|
| |||||
|
| valve. | |||||
the component cooling fan. |
|
| |||||
|
| a) 1st valve (safety) on the gas | |||||
A. | Power to motor speed (Hi/Low) relay (R1) |
|
| ||||
|
| valve energized. | |||||
| normally open (N.O.) contacts and to |
|
| ||||
|
|
|
| ||||
| common (C) on hold relay (R2). Power is |
|
| NOTE: Gas does not flow to the | |||
| then connected through hold relay (R2) |
|
| burner until the 2nd valve (main) | |||
| normally closed (N.C.) contacts to motor |
|
| is energized. | |||
| speed (Hi/Low) relay (R1) coil. |
|
| 3) Component cooling fan. | |||
| 1) Motor speed (Hi/Low) relay (R1) is |
|
| ||||
| 4. | The oven will remain in this condition until the | |||||
| energized and contacts change state. | ||||||
|
| power switch (S1) is turned to the OFF or ON | |||||
| a. Power is connected through |
| |||||
|
| position. | |||||
| motor speed (Hi/Low) relay | WKGC, WKGCX | |||||
| normally open (N.O.) contacts, | ||||||
| (Roast & Hold Standard on Computer Model) | ||||||
| through function switch (S3) to | ||||||
|
|
|
| ||||
| Convection fan motor. | Schematic diagram 10835 will be used to explain the | |||||
| a) | Convection fan motor | |||||
| electrical sequence of operation for both the ROAST | ||||||
|
| energized. | cycle (normal cooking) and the ROAST & HOLD | ||||
| NOTE: If function switch (S3) is | cycle. |
| ||||
|
|
|
| ||||
| set to Normal ROAST cycle, fan | Roast Cycle (Normal Cooking) | |||||
| speed will be high; if set to | 1. | Conditions. | ||||
| ROAST & HOLD cycle, fan | ||||||
|
|
|
| ||||
| speed will be low. |
| A. | Oven connected to correct voltage. | |||
| b) When Convection fan motor |
|
| 1) L1 (HOT) to power switch (S1). | |||
|
| reaches operating speed the |
|
| 2) L2 (NEUTRAL or SECOND LINE) to | ||
|
| centrifugal switch on the |
|
| |||
|
|
|
| one side of the following components: | |||
|
| motor closes but no power |
|
| |||
|
|
|
| oven cavity lights, convection fan | |||
|
| is available for connection to |
|
| |||
|
|
|
| motor common (C), transformer | |||
|
| other components. |
|
| |||
|
|
|
| primary (T1), component cooling fan | |||
B. Power to one side of the hold thermostat |
|
| |||||
|
| and the heat relay coil (R1). | |||||
| contacts but is not transferred to other |
| B. | Oven properly grounded. | |||
| components due to oven cavity |
| |||||
|
|
|
| ||||
| temperature above 160°F (thermostat |
|
| 1) Ground (GND) to one side of the | |||
| OPEN). |
|
|
|
|
| following components: computer |
C. | Power to terminal 7 on the solid state |
|
| control case, NO IGNITION light, | |||
|
| transformer secondary (T1), ignition | |||||
| temperature control but is not transferred |
|
| ||||
|
|
| control module, the 1st valve (safety) | ||||
| to other components due to temperature |
|
| and 2nd valve (main) on the dual | |||
| control not being powered. |
|
| solenoid gas valve and computer | |||
3. If door switch is CLOSED (doors closed), power |
|
| |||||
|
| control pin 9 | |||||
is supplied to one side of the following |
| C. | Gas supply valve ON. | ||||
components: Power ON light (Amber), oven |
| ||||||
|
|
| |||||
light switch (S2), Normal ROAST timer terminal |
| D. | Gas combination control valve ON. | ||||
1, ROAST & HOLD timer terminal 1, |
| E. | Power switch (S1) OFF. | ||||
transformer primary (T1) and component |
| ||||||
|
|
| |||||
cooling fan. |
|
|
|
| F. | Computer control is setup properly and | |
| 1) Power ON light (Amber) comes ON. |
|
| ready to use. | |||
|
| G. | Oven light switch (S2) ON/OFF (position | ||||
| 2) Transformer (T1) energized. |
| |||||
|
|
| has no affect on the function of the ROAST | ||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| cycle). |
|
|
|
|
|
| H. | High limit switch CLOSED. |
F32700 (February 2006) |
|
| Page 44 of 64 |
|
| ||
|
|
|
|