Wolf WKGC 126622, WKGX 126623 Roast & Hold Standard on Computer Model, Roast Cycle Normal Cooking

Models: WKGX 126623 WKGD 126621 WKGCX 126625 WKG 126620 WKGC 126622 WKGDX 126624

1 64
Download 64 pages 8.19 Kb
Page 44
Image 44

FULL SIZE GAS CONVECTION OVENS - ELECTRICAL OPERATION

2. Power Switch (S1) turned to OVEN COOL.

 

 

a. Power (24VAC) to one side of

NOTE: With door switch contacts OPEN (doors

 

 

the following components: heat

 

 

relay (R3) normally open (N.O.)

open), the convection fan motor will still run and

 

 

 

 

contacts, high limit --- connected

continue to cool the oven. However, power would be

 

 

 

 

through the normally closed

removed from the following components: Power ON

 

 

 

 

(N.C.) contacts to the 1st valve

light (goes out), Normal ROAST timer, ROAST &

 

 

(safety) on the dual solenoid gas

HOLD timer, transformer T1 (de-energized) and to

 

 

 

 

valve.

the component cooling fan.

 

 

 

 

a) 1st valve (safety) on the gas

A.

Power to motor speed (Hi/Low) relay (R1)

 

 

 

 

valve energized.

 

normally open (N.O.) contacts and to

 

 

 

 

 

 

 

common (C) on hold relay (R2). Power is

 

 

NOTE: Gas does not flow to the

 

then connected through hold relay (R2)

 

 

burner until the 2nd valve (main)

 

normally closed (N.C.) contacts to motor

 

 

is energized.

 

speed (Hi/Low) relay (R1) coil.

 

 

3) Component cooling fan.

 

1) Motor speed (Hi/Low) relay (R1) is

 

 

 

4.

The oven will remain in this condition until the

 

energized and contacts change state.

 

 

power switch (S1) is turned to the OFF or ON

 

a. Power is connected through

 

 

 

position.

 

motor speed (Hi/Low) relay

WKGC, WKGCX

 

normally open (N.O.) contacts,

 

(Roast & Hold Standard on Computer Model)

 

through function switch (S3) to

 

 

 

 

 

Convection fan motor.

Schematic diagram 10835 will be used to explain the

 

a)

Convection fan motor

 

electrical sequence of operation for both the ROAST

 

 

energized.

cycle (normal cooking) and the ROAST & HOLD

 

NOTE: If function switch (S3) is

cycle.

 

 

 

 

 

 

set to Normal ROAST cycle, fan

Roast Cycle (Normal Cooking)

 

speed will be high; if set to

1.

Conditions.

 

ROAST & HOLD cycle, fan

 

 

 

 

 

speed will be low.

 

A.

Oven connected to correct voltage.

 

b) When Convection fan motor

 

 

1) L1 (HOT) to power switch (S1).

 

 

reaches operating speed the

 

 

2) L2 (NEUTRAL or SECOND LINE) to

 

 

centrifugal switch on the

 

 

 

 

 

 

one side of the following components:

 

 

motor closes but no power

 

 

 

 

 

 

oven cavity lights, convection fan

 

 

is available for connection to

 

 

 

 

 

 

motor common (C), transformer

 

 

other components.

 

 

 

 

 

 

primary (T1), component cooling fan

B. Power to one side of the hold thermostat

 

 

 

 

and the heat relay coil (R1).

 

contacts but is not transferred to other

 

B.

Oven properly grounded.

 

components due to oven cavity

 

 

 

 

 

 

temperature above 160°F (thermostat

 

 

1) Ground (GND) to one side of the

 

OPEN).

 

 

 

 

 

following components: computer

C.

Power to terminal 7 on the solid state

 

 

control case, NO IGNITION light,

 

 

transformer secondary (T1), ignition

 

temperature control but is not transferred

 

 

 

 

 

control module, the 1st valve (safety)

 

to other components due to temperature

 

 

and 2nd valve (main) on the dual

 

control not being powered.

 

 

solenoid gas valve and computer

3. If door switch is CLOSED (doors closed), power

 

 

 

 

control pin 9 (C3-9).

is supplied to one side of the following

 

C.

Gas supply valve ON.

components: Power ON light (Amber), oven

 

 

 

 

light switch (S2), Normal ROAST timer terminal

 

D.

Gas combination control valve ON.

1, ROAST & HOLD timer terminal 1,

 

E.

Power switch (S1) OFF.

transformer primary (T1) and component

 

 

 

 

cooling fan.

 

 

 

 

F.

Computer control is setup properly and

 

1) Power ON light (Amber) comes ON.

 

 

ready to use.

 

 

G.

Oven light switch (S2) ON/OFF (position

 

2) Transformer (T1) energized.

 

 

 

 

has no affect on the function of the ROAST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cycle).

 

 

 

 

 

 

H.

High limit switch CLOSED.

F32700 (February 2006)

 

 

Page 44 of 64

 

 

 

 

 

 

Page 44
Image 44
Wolf WKGC 126622, WKGDX 126624, WKGX 126623, WKGD 126621 Roast & Hold Standard on Computer Model, Roast Cycle Normal Cooking