White Rodgers 1F86-0471, 1F80-0471 specifications INSTALLER/CONFIGURATION Menu

Page 4

INSTALLER/CONFIGURATION MENU

Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the

next menu item. Press or to change a menu item.

INSTALLER/CONFIGURATION MENU

MENU

 

 

PRESS

DISPLAYED

Press

or

to

 

REF.

HP

SS

BUTTON

(FACTORY DEFAULT)

select from listed options

COMMENTS

 

 

 

 

 

 

 

 

1

1

 

MENU

On (Cool O)

Heat b On

 

Reversing Valve Output (Heat Pump switch S8

 

 

 

 

 

 

 

 

must be in the Heat Pump HP position)

2

2

1

MENU

P (2)

 

P 3, P 0

 

Selectable Programs Per Week

 

 

 

 

 

 

 

 

(For programmable thermostat only)

 

 

 

 

 

 

 

3

3

2

MENU

Cool Saving CS (OFF)

Cool Saving CS On

Select Cool Savings on or off

 

 

 

 

 

 

 

 

 

 

 

 

CS (3)

6, 5, 4, 2, 1

 

Selects Cool Savings value 1 (low) to 6 (high)

4

4

3

MENU

E (On)

 

E OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

on or off

 

 

 

 

 

 

 

 

 

5

 

4

MENU

CR Heat

 

FA, SL

 

Adjustable Anticipation (Heat) (only when

 

 

 

 

(ME)

 

 

 

heat pump switch is at the SS position)

 

 

 

 

 

 

 

 

 

6

 

5

MENU

CR Cool

 

SL

 

Adjustable Anticipation (Cool) (only when

 

 

 

 

(FA)

 

 

 

heat pump switch is at the SS position)

 

 

 

 

 

 

 

 

 

7

5

 

MENU

CR Heat Pump

 

SL

 

Adjustable Anticipation (Heat Pump) (only

 

 

 

 

(FA)

 

 

 

when heat pump switch is at the HP position)

 

 

 

 

 

 

 

 

 

8

6

6

MENU

CL (OFF)

 

CL On

 

Compressor Lockout Time

 

 

 

 

 

 

 

 

9

7

7

MENU

Auto Heat

Heat Cool Off,

 

System Mode Configuration

 

 

 

 

Cool Off

Heat Off with Fan icon,

with Automatic Changeover

 

 

 

 

 

Heat Off without Fan

 

 

 

 

 

 

icon, Cool Off,

 

 

 

 

 

 

 

 

Auto Off

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool Off Heat

Heat Off with Fan icon,

System Mode Configuration

 

 

 

 

 

Heat Off without

 

without Automatic Changeover

 

 

 

 

 

Fan icon, Cool Off

 

10

8

8

MENU

L (On)

 

L OFF

 

Selects Display Light on or off

 

 

 

 

 

 

 

11

9

9

MENU

0 HI

1 HI, 2 HI, 3HI, 4 HI,

Adjustable Ambient Temperature Display

 

 

 

 

 

1 LO, 2 LO, 3 LO, 4 LO

 

 

 

 

 

 

 

 

 

 

12

10

10

MENU

F

 

C

 

Selects Fahrenheit/Celcius Temperature Display

 

 

 

 

 

 

 

13

11

11

MENU

Change Filter (OFF)

Change Filter On

Selects Filter Change-out Indicator

 

 

 

 

 

 

 

 

 

 

 

Change Filter 200 h

25 h to 1975 h in

When on, selects time in 25 hour increments

 

 

 

 

 

25-hour increment

 

 

 

 

 

 

 

 

 

 

14

12

12

RUN

 

 

 

 

Returns to Normal Operation

 

 

 

 

 

 

 

 

 

1)Select Reversing Valve Output (Heat Pump switch S8 must be set at HP) – The O/B option is factory set at "O" position. This will accommodate the majority of heat pump applications, which require the changeover relay to be energized in COOL. If the thermostat you are replac- ing or the heat pump being installed with this thermostat requires a "B" terminal, to energize the changeover relay in HEAT, the O/B option should be set at "B" position.

2)Program Options: This control can be configured for 5/2 day or 5/1/1 day programming or non-programming mode. The default setting is P2, indicating 5/2 day programming. The programs per week can be toggled to P3 or P0 by

pressing the or keys. A selection of 0 Days for non-programmable will eliminate the need for EMR, and that step in the menu will be skipped.

3)Select Cool Savings™: With Cool Savings™ enabled, the thermostat will make small adjustments to the setpoint temperature during periods of high demand to reduce AC

system running time and save energy. When the cooling system has been running for more than 20 minutes, humidity in the home will be lower and a higher setpoint temperature will feel comfortable. After 20 minutes of run time, the thermostat will start increasing the setpoint temperature in steps of less than one degree as the system continues to run. These adjustments will eventu- ally cause the system to satisfy the thermostat to turn the system off and reduce the energy consumption. When the Cool Savings™ feature is active and making adjust- ments, the display will show “Save” next to the setpoint temperature. The amount of the adjustments to the setpoint temperature is dependent on the Cool Savings™ value that is set, 1 being the least adjustment and 6 being the most adjustment. With this feature set to OFF, no change will occur when the AC system is continuously running during the periods of high demand. Periods of high demand will normally occur during the late afternoon and early evening on the hottest days of the summer.

4

Image 4
Contents Specifications ApplicationsSave these instructions for future use IndexInstallation Wiring ConnectionsProgramming and Configuration Items Thermostat Quick ReferenceHome Screen Description Displays Run Schedule, Schedule, or MenuINSTALLER/CONFIGURATION Menu 11Select Temperature Display Adjustment 4 LO to 4 HI Operating Your Thermostat Planning Your Program Important Energy Saving Factory Pre-ProgramWorksheet for Re-Programming 5/2 Day and 5+1+1 Day Program Troubleshooting Symptom Possible Cause Corrective ActionReset Operation St. Louis, Missouri