White Rodgers 1F85-0471, 1F85CA-0471 specifications INSTALLER/CONFIGURATION Menu, Press

Page 5

INSTALLER/CONFIGURATION MENU

With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show

item #1 in the table below. Press Menu button to advance to the next menu item. Press or to change an item option. Shaded items not available on 1F83 model.

INSTALLER/CONFIGURATION MENU

MENU

 

 

PRESS

DISPLAYED

Press

 

 

or

 

 

to

 

 

 

 

 

 

 

 

REF.

HP

SS

BUTTON

(FACTORY DEFAULT)

select from listed options

COMMENTS

1

1

1

MENU

(MS 2)

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2 No Heat Pump),

 

 

 

 

 

 

 

 

 

 

 

 

Heat Pump 1 (HP 1, 1 compressor),

 

 

 

 

 

 

 

 

 

 

 

 

or Single Stage (SS 1), Heat Pump 2 (HP 2, 2

 

 

 

 

 

 

 

 

 

 

 

 

compressor or 2 speed compressor)

2

2

2

MENU

(GAS) for SS or MS

 

 

ELE

 

GAS setting: furnace controls the blower

 

 

 

 

(ELE) for HP

 

 

 

 

 

 

 

ELE setting: thermostat controls the blower

3

3

3

MENU

CS (0)

1, 2, 3, 4, 5, 6

 

Selects Cool Savings

 

 

 

 

(Disabled)

 

 

 

 

 

 

 

Value 1 (low) to 6 (high), Value 0 Disables Feature

4

4

4

MENU

E (On)

 

 

OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

 

 

 

 

On or OFF. NA 1F83.

5

5

MENU

CR Heat (ME)

 

SL, FA

 

Adjustable Anticipation:

 

 

 

 

 

 

 

 

 

 

 

 

Selects heating cycle rate for MS or SS

6

5

MENU

CR Heat Pump

 

SL, FA

 

Adjustable Anticipation (Heat Pump) (only

 

 

 

 

(ME)

 

 

 

 

 

 

 

when heat pump selected in #1)

7

6

6

MENU

CR Cool (ME)

 

SL, FA

 

Adjustable Anticipation: Selects the cycle rate for

 

 

 

 

or

 

 

 

 

 

 

 

cooling (only when MS 2 or SS 1 is selected in

 

 

 

 

CR Emer (FA)

 

 

SL

 

item 1.) or Selects the cycle rate for Emergency

 

 

 

 

 

 

 

 

 

 

 

 

mode and Auxiliary stage if Heat Pump is

 

 

 

 

 

 

 

 

 

 

 

 

selected in item 1.

8

7

7

MENU

CL (OFF)

 

CL On

 

Compressor Lockout Time

9

8

8

MENU

Heat Auto

Heat Cool Off,

 

System Mode Configuration

 

 

 

 

Cool Off

Heat Off with Fan icon,

with Automatic Changeover capability

 

 

 

 

 

Heat Off without Fan icon

 

 

 

 

 

 

Cool Off, Auto Off

 

10

9

9

MENU

dL (On)

 

dL OFF

 

Selects Display Light On or OFF

11

10

10

MENU

0

1 HI, 2 HI, 3 HI, 4 HI,

Adjustable Ambient Temperature Display

 

 

 

 

(current temperature)

1 LO, 2 LO, 3 LO, 4 LO

 

12

11

11

MENU

°F

 

 

°C

 

Selects Fahrenheit/Celsius Temperature Display

13

12

12

MENU

L Heat

L 62 to L 89

 

Selects Limited HEAT Range

 

 

 

 

(90)

 

 

 

 

 

 

 

 

14

13

13

MENU

L Cool

L 46 to L 82

 

Selects Limited COOL Range

 

 

 

 

(45)

 

 

 

 

 

 

 

 

15

14

14

MENU

P3

 

P0, P2

 

Defaults for 5-1-1 programming (P3) but non-

 

 

 

 

 

 

 

 

 

 

 

 

programmable (PO) or 5-2 programming (P2)

 

 

 

 

 

 

 

 

 

 

 

 

is available on most models. NA 1F83.

16

15

15

MENU

Heat AS (On)

 

 

OFF

 

Automatic Schedule for heat mode. NA 1F83.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Cool only system.

17

16

16

MENU

Cool AS (On)

 

 

OFF

 

Automatic Schedule for cool mode. NA 1F83.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Heat only system.

18

17

MENU

Heat FA (On)

 

 

OFF

 

Fast Heat option may be disabled by

 

 

 

 

 

 

 

 

 

 

 

 

selecting OFF. NA to SS config.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Cool only system.

19

18

MENU

Cool FA (On)

 

 

OFF

 

Fast Cool option may be disabled by

 

 

 

 

 

 

 

 

 

 

 

 

selecting OFF. NA to SS config.

 

 

 

 

 

 

 

 

 

 

 

 

NA to Heat only system.

20

19

17

MENU

CA (OFF)

 

 

On

 

Selects active Comfort Alert On or OFF.

 

 

 

 

 

 

 

 

 

 

 

 

Requires CA II Module. (1F85CA only)

21

20

18

MENU

dS (On)

 

 

OFF

 

Selects Automatic daylight Savings Time option

 

 

 

 

 

 

 

 

 

 

 

 

On or OFF. NA 1F83.

22

21

19

MENU

Change Filter (OFF)

 

 

On

 

Selects Filter Change-out Indicator On or OFF.

 

 

 

MENU

Change Filter (200 h)

25-1975 h

 

Change Filter time in 25 hour increments. This

 

 

 

 

 

 

 

 

 

 

 

 

menu only appears if On is selected in above.

23

22

20

MENU

Cool On (o)

Heat On (b)

 

Selects operation of the reversing valve terminal

 

 

 

 

 

 

 

 

 

 

 

 

(O/B) output as an O or B terminal.

24

23

21

RUN

 

 

 

 

 

 

 

 

Returns to Normal Operation

 

 

 

SCHED

 

 

 

 

 

 

 

 

 

5

Image 5
Contents Save these instructions for future use SpecificationsApplications Wiring Connections InstallationInstalling New Thermostat Remove Old ThermostatSingle Stage and Multi-Stage Connections Wiring DiagramsHeat Pump Connections Programming and Configuration Items Thermostat Quick ReferenceHome Screen Description Press INSTALLER/CONFIGURATION MenuSelect Temperature Display Adjustment 4 LO to 4 HI Operating Your Thermostat Enter the Cooling Program Enter the Heating ProgramEnergy Saving Energy Star Factory Pre-Program Planning Your Program ImportantReset Operation TroubleshootingComfort Alert Yellow Alert Codes Comfort Alert CodesPage Homeowner Help Line

1F85CA-0471, 1F85-0471 specifications

The White Rodgers 1F85-0471 and 1F85CA-0471 are sophisticated digital thermostats designed to enhance home heating and cooling efficiency while providing user-friendly operation. These models reflect a commitment to advanced technology and ease of use, making them popular choices among homeowners seeking comfort and energy savings.

One of the main features of the 1F85 series is its touchscreen interface. The bright, clear display offers intuitive navigation, allowing users to effortlessly adjust temperature settings and program schedules. Unlike traditional thermostats, the touchscreen eliminates the complexity of buttons and knobs, making it accessible for all demographics, including those who may not be tech-savvy.

The 1F85-0471 and 1F85CA-0471 models also boast advanced programming capabilities. They provide 7-day programming options, allowing for customized heating and cooling schedules throughout the week. Homeowners can program different settings for weekdays and weekends to reduce energy consumption without sacrificing comfort. This flexibility is particularly beneficial for families with varied schedules, ensuring efficient climate control at all times.

Another technology feature is the built-in adaptive recovery function. This capability learns how long it takes to reach the desired temperature and begins the heating or cooling process early, ensuring that the home is comfortable by the scheduled time. This smart feature maximizes energy efficiency and minimizes temperature fluctuations, further enhancing comfort levels.

The 1F85 series is designed to work with virtually all HVAC systems, including gas, oil, and electric systems, making it a versatile choice for various setups. The compatibility with multi-stage systems ensures that homeowners can make the most out of their heating and cooling systems.

Among its other characteristics, the thermostat offers a real-time clock, filter change reminders, and an Energy Savings mode, which can help homeowners reduce energy costs by adjusting temperature settings during peak periods.

Overall, the White Rodgers 1F85-0471 and 1F85CA-0471 thermostats combine modern technology, flexibility, and efficiency, catering to the needs of today’s energy-conscious consumers. With their intuitive design and advanced features, these thermostats can significantly enhance the comfort of any home while promoting energy savings.