White Rodgers 1F80-0261 specifications Wiring Diagrams, Energy Management Recovery EMR

Page 3

INSTALLATION

ENERGY MANAGEMENT RECOVERY

(EMR)

When the EMR feature is activated the thermostat’s microcomputer calculates the time it will take to change the room temperature to the next heat or cool program setting. Then the thermostat will start the system before the next programmed period so that the desired temperature is reached at or near the beginning of the period (the thermostat calculates 15 minutes for every 1°F temperature change). This feature provides better efficiency by allowing gradual temperature changes.

For example: The thermostat is programmed to provide an overnight heating temperature of 66°F, and during the next program period, beginning at 6:00 AM, the programmed temperature is 70°F. With EMR activated, the thermostat will

automatically start the heating system at 5:00 AM, so that the programmed temperature of 70°F is reached by about 6:00 AM.

If the overnight room temperature drops only to 68°F, the thermostat will start the system at 5:30 to reach the programmed temperature of 70°F at 6:00.

The thermostat is shipped with the EMR feature active, which means that the thermostat will start the heating system before the beginning of the next program period.

To deactivate the EMR function, see the Configuration menu on Page 5). The thermostat will then wait until the programmed time to start the system for a temperature change.

WIRING DIAGRAMS

Optional Jumper for

Single Stage Heat Pump

O/B

Y

G

W

C

Changeover

 

Fan

 

 

Relay*

Compressor

 

Optional

Relay

 

 

Heat Relay

 

Contactor

 

 

 

 

 

 

 

 

*Changeover Relay is energized in COOL when O/B switch is in the “O” position Changeover Relay is energized in HEAT when O/B switch is in the “B” position

THERMOSTAT

R

SYSTEM

24 VAC

 

 

 

 

 

Hot

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

TRANSFORMER

(Class II Current Limited)

Figure 2. Typical wiring diagram for single transformer single stage systems

NOTE

If safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits.

Optional Jumper for

Single Stage Heat Pump

THERMOSTAT

 

 

 

 

 

 

 

O/B

Y

 

G

W

 

 

C

R

 

 

 

 

CUT AND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAPE OFF!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changeover

 

 

 

Fan

 

 

 

 

 

 

 

 

Limit or

 

 

 

 

 

HOT

 

 

 

 

Relay*

 

 

 

Relay

 

 

 

 

 

 

Optional

 

Safety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switches

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

Compressor

 

 

 

 

Heat Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWO COMMONS MUST

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Changeover Relay is energized in COOL when O/B switch is in the “O” position

 

 

 

 

TRANSFORMER

 

 

BE JUMPERED TOGETHER!

 

 

 

 

 

(Class II Current Limited)

Changeover Relay is energized in HEAT when O/B switch is in the “B” position

 

 

 

 

 

 

 

Figure 3. Typical wiring diagram for two transformer single stage systems with NO safety circuits

3

Image 3
Contents Specifications PrecautionsApplications Installation Energy Management Recovery EMR Wiring DiagramsIndicates days of the week Thermostat Buttons and SwitchesThermostat Quick Reference DisplaySS Heat SS Cool INSTALLER/CONFIGURATION MenuOperation Check Thermostat OperationManual Operation Entering Your Program ProgrammingProgramming Your Thermostat Planning Your ProgramEnter Cooling Program Check Your ProgrammingReset Operation TroubleshootingPage Page Homeowner Help Line

1F80-0261 specifications

The White Rodgers 1F80-0261 is a programmable thermostat known for its user-friendly interface and advanced features that cater to modern heating and cooling needs. With its sleek design and intuitive controls, it offers a seamless blend of functionality and aesthetics, making it an attractive choice for homeowners looking to optimize their HVAC systems.

One of the standout features of the 1F80-0261 is its 7-day programming capability. This allows users to create specific heating and cooling schedules for each day of the week, accommodating varying routines and preferences. Each day can have different settings for morning, daytime, evening, and night periods, promoting energy efficiency and comfort. The thermostat also has a vacation hold feature that allows homeowners to program a temporary setting while they are away, preventing unnecessary energy consumption.

The 1F80-0261 utilizes advanced technologies to enhance its performance. The thermostat employs a precise temperature control mechanism that ensures consistent and accurate heating and cooling. Additionally, it features an energy-saving mode that helps reduce energy bills by optimizing system performance without sacrificing comfort. This mode is particularly beneficial during peak energy usage hours.

The thermostat's large, easy-to-read display improves usability, allowing users to view current temperatures and settings at a glance. Backlighting ensures visibility even in low-light conditions, further enhancing user experience. The graphical interface is designed to guide users through programming options, making it accessible for individuals of all technical skill levels.

Another notable characteristic is the compatibility of the 1F80-0261 with a wide range of heating and cooling systems, including conventional heating systems and heat pumps. This versatility enables users to integrate the thermostat into their existing infrastructure seamlessly.

Additionally, the 1F80-0261 offers filter change reminders that alert users when it's time to replace or clean their system’s filters. This feature helps maintain air quality and system efficiency by ensuring that filters are regularly attended to.

In summary, the White Rodgers 1F80-0261 is a programmable thermostat that combines advanced programming features, user-friendly design, and energy-efficient technology. Its ability to cater to diverse HVAC systems, alongside its focus on improving comfort and reducing energy costs, makes it a noteworthy option for any homeowner seeking control over their indoor climate.