White Rodgers 1F80-0261 specifications INSTALLER/CONFIGURATION Menu, SS Heat SS Cool

Page 5

INSTALLER/CONFIGURATION MENU

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.

To enter the menu: Set your thermostat to OFF and press the and buttons simultaneously. The display will show the first item in the configuration menu. Press RUN/HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press PRGM. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.

Configuration Menu

Menu

Press

Displayed

Press

or

Comments

Reference

Key

(Factory

to select from

 

Number

 

Default)

listed options

 

 

 

 

 

 

 

1

and

SS

 

HP

Select Single Stage (SS) or

 

 

 

 

 

Heat Pump (HP, 1 compressor)

 

 

 

 

 

 

2

RUN/HOLD*

CS

 

On

Select Cool Savings Feature On or OFF

 

 

(OFF)

 

 

 

 

 

 

 

 

 

RUN/HOLD*

CS

1, 2, 3, 4, 5, 6

If CS selected On, selects Cool Savings value

 

 

(3)

 

 

 

 

 

 

 

 

 

3

RUN/HOLD*

E

 

OFF

Select Energy Management Recovery On or OFF

 

 

(On)

 

 

 

 

 

 

 

 

4

RUN/HOLD*

CR Heat

FA, SL

Select Adjustable Anticipation, cycle rate,

 

 

(ME)

 

 

Heat Single Stage

 

 

 

 

 

 

5

RUN/HOLD*

CR Cool

 

SL

Select Adjustable Anticipation, cycle rate,

 

 

(FA)

 

 

Cool Single Stage

 

 

 

 

 

 

6

RUN/HOLD*

CL

 

On

Select Compressor lockout OFF or On

 

 

(OFF)

 

 

 

 

 

 

 

 

 

7

RUN/HOLD*

L

 

OFF

Select Display Light On or OFF

 

 

(On)

 

 

 

 

 

 

 

 

8

RUN/HOLD*

Temp

4 LO to

Select temperature display adjustment higher or lower

 

 

(0 HI)

 

4 HI

 

 

 

 

 

 

 

9

RUN/HOLD*

oF

 

oC

Select oF / oC Display (temperature units in Fahrenheit

 

 

 

 

 

or Celsius)

 

 

 

 

 

 

10

RUN/HOLD*

Change Filter

 

On

Select filter replacement indicator OFF or On

 

 

(OFF)

 

 

 

 

 

 

 

 

 

RUN/HOLD*

Change Filter

25 to 1975

If Change Filter selected On, selects time interval for

 

 

(200 h)

 

 

Change Filter Indicator. (in 25 hour increments)

 

 

 

 

 

 

11

RUN/HOLD*

 

 

 

Returns to normal operation

 

 

 

 

 

 

*Press RUN/HOLD to advance to next item or TIME to move backwards to previous item

1)System Configuration - Selects SS (Single Stage) or HP (Heat Pump) operating mode. Default configuration is SS. For Heat Pump operation choose HP.

2)Select CS (Cool Savings™) - With Cool Savings™ enabled, the thermostat will make small adjustments to the Setpoint temperature during periods of high demand to reduce cooling system running time and save energy. When the cooling system has been running for more than 20 minutes, humidity in the home will be lower and a higher setpoint temperature will feel comfortable. After 20 minutes of run time, the thermostat will start increasing the setpoint temperature in steps of less than one degree as the system continues to run. These adjustments will eventually cause the system to satisfy the thermostat and turn the system off to reduce the energy consumption. When the Cool Savings feature is active and making adjustments, the display will show “Save”. The amount of the adjustments to the setpoint temperature is dependent on the Cool Savings value that is set, 1 being the least adjustment and 6 being the most adjustment. With this feature set to OFF, no change will occur when the cooling system is continuously running during the periods of high demand. Periods of high demand will normally occur during the late afternoon and early evening on the hottest days of the summer.

3)Select Energy Management Recovery - Energy Management Recovery (E) On enables the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint. Example: E On is selected and your heating is programmed to 65o at night and 70o at 7AM. If the building temperature is 65o, the difference between 65o and 70o is 5o. Allowing 5 minutes per degree, the thermostat Setpoint will change to 70o at 6:35 AM. Cooling allows more time per degree, because it takes longer to reach set temperature.

4 & 5) Select Cycle Rate Selection - The factory default setting for Single Stage Heat is Medium Cycle (ME). For Single Stage Cool the default setting is fast (FA). To change

cycle rate, press the and buttons.

The cycle rate differentials for different settings are:

MODE

Fast

Medium

Slow

 

(FA)

(ME)

(SL)

SS Heat

0.6°F

0.8°F

1.2°F

SS Cool

1.2°F

-

1.7°F

5

Image 5
Contents Applications SpecificationsPrecautions Installation Energy Management Recovery EMR Wiring DiagramsThermostat Quick Reference Thermostat Buttons and SwitchesDisplay Indicates days of the weekSS Heat SS Cool INSTALLER/CONFIGURATION MenuManual Operation OperationCheck Thermostat Operation Programming Your Thermostat ProgrammingPlanning Your Program Entering Your ProgramEnter Cooling Program Check Your ProgrammingReset Operation TroubleshootingPage Page Homeowner Help Line

1F80-0261 specifications

The White Rodgers 1F80-0261 is a programmable thermostat known for its user-friendly interface and advanced features that cater to modern heating and cooling needs. With its sleek design and intuitive controls, it offers a seamless blend of functionality and aesthetics, making it an attractive choice for homeowners looking to optimize their HVAC systems.

One of the standout features of the 1F80-0261 is its 7-day programming capability. This allows users to create specific heating and cooling schedules for each day of the week, accommodating varying routines and preferences. Each day can have different settings for morning, daytime, evening, and night periods, promoting energy efficiency and comfort. The thermostat also has a vacation hold feature that allows homeowners to program a temporary setting while they are away, preventing unnecessary energy consumption.

The 1F80-0261 utilizes advanced technologies to enhance its performance. The thermostat employs a precise temperature control mechanism that ensures consistent and accurate heating and cooling. Additionally, it features an energy-saving mode that helps reduce energy bills by optimizing system performance without sacrificing comfort. This mode is particularly beneficial during peak energy usage hours.

The thermostat's large, easy-to-read display improves usability, allowing users to view current temperatures and settings at a glance. Backlighting ensures visibility even in low-light conditions, further enhancing user experience. The graphical interface is designed to guide users through programming options, making it accessible for individuals of all technical skill levels.

Another notable characteristic is the compatibility of the 1F80-0261 with a wide range of heating and cooling systems, including conventional heating systems and heat pumps. This versatility enables users to integrate the thermostat into their existing infrastructure seamlessly.

Additionally, the 1F80-0261 offers filter change reminders that alert users when it's time to replace or clean their system’s filters. This feature helps maintain air quality and system efficiency by ensuring that filters are regularly attended to.

In summary, the White Rodgers 1F80-0261 is a programmable thermostat that combines advanced programming features, user-friendly design, and energy-efficient technology. Its ability to cater to diverse HVAC systems, alongside its focus on improving comfort and reducing energy costs, makes it a noteworthy option for any homeowner seeking control over their indoor climate.