White Rodgers 1E50N-303 NEW Thermostat Operation, Specifications, Troubleshooting

Page 2

6 NEW THERMOSTAT OPERATION

This thermostat is easy to operate. After power is turned on, raise temperature abo- ve room temperature to turn the heating system on. Lower temperature below room temperature to turn heating system off.

7 SPECIFICATIONS

ELECTRICAL DATA

 

Switch Rating

24 VAC (30 VAC max.)

Heating

0.15 to 1.2 Amps

Anticipator Rating:

 

Heating

Adjustable from 0.15 to 1.2 Amps

Heat

Anticipator (adjustable)

WR

Heating

System

24 VAC

THERMOSTAT

SYSTEM

Hot

120 VAC

Neutral

THERMAL DATA:

 

Temperature Range

50°F to 90°F (10°C to 32°C)

Operating Humidity Range

0 – 90% noncondensing

Figure 3. Typical wiring for single transformer heating system

8 TROUBLESHOOTING

Symptom

Possible Cause

Corrective Action

 

 

 

 

No Heat/ No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety interlock or door switch.

 

 

panel loose or not properly installed.

 

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2. Broken or melted anticipator wire.

Excessive current or dead short in system. Have a qualifi ed service person check the system

 

 

 

before replacing thermostat.

 

3.

Loose connection to thermostat or

Verify thermostat and system wires are securely attached.

 

 

system.

 

 

4. Thermostat or heating system requires

Your furnace manufacturer or service person can describe how to test the heating system to

 

 

replacement or service.

verify it is operating correctly. If the heating system is capable of operation and the no heat

 

 

 

condition persists, replace the thermostat.

 

5. Setpoint temperature below room

Raise temperature above room temperature.

 

 

temperature.

 

 

 

 

 

Intermittent Heat

1.

Furnace Lock-Out Condition

Many furnaces have safety devices that shut the system down when a lock-out condition

 

 

 

occurs. If the heat works intermittently contact the furnace manufacturer or local service

 

 

 

person for assistance.

 

 

 

 

Heat or Fan Runs

1.

Possible short in wiring.

Check each wire connection to the thermostat to verify it is neatly looped under the terminals.

Constantly.

2.

Possible short in thermostat.

No extra wire should stick out from under the terminals.

 

 

 

3.

Possible short in heat/cool/fan system.

 

 

 

 

Furnace Cycles Too

See Step 5, Adjusting the Anticipator.

The anticipation setting is the only adjustment that effects the heating cycle rate. If an

Fast or Too Slow

 

 

acceptable cycle rate is not achieved using the anticipator contact a local service person for

(Narrow or wide

 

 

additional suggestions. The location of the thermostat, size of the Heat/Cool System and

temperature swing)

 

 

current draw can infl uence the cycle rate.

 

 

 

 

Thermostat Setting

1.

Thermostat thermometer setting

The thermometer can be adjusted by using a standard slotted screwdriver. Turn the

and Thermostat

 

requires adjustment.

thermometer pointer screw located inside the front cover to change the setting. For calibrating

Thermometer Disagree

2.

Thermostat setting lever requires

the setting lever contact a local heating and cooling service person.

 

 

 

 

calibration.

 

 

 

 

 

Adjusting Thermometer

1.

Thermostat thermometer disagrees

The thermometer on the thermostat is accurately calibrated at our factory but you can adjust

 

 

with other room thermometers.

it by using a standard slotted screwdriver. Turn the thermometer pointer screw located inside

 

 

 

the front cover to change the setting.

 

 

 

 

The Emerson logo is a trademark and service mark of Emerson Electric Co.

Image 2
Contents Your Thermostat Replaces Thermostat FeaturesMounting and Wiring PreparationsNEW Thermostat Operation SpecificationsTroubleshooting DU Fonctionnement DépannageSpécifications Câblage ET Montage Chauffage DE ’ANTICIPATION DE RéglageCaractéristiques Préparatifs

1E50N-303 specifications

The White Rodgers 1E50N-303 is a versatile and reliable thermostat designed for both residential and commercial HVAC systems. This device features advanced technologies that improve energy efficiency and enhance temperature control, making it a popular choice among homeowners and HVAC professionals alike.

One of the main features of the 1E50N-303 is its user-friendly interface. The thermostat is equipped with a large display that clearly shows the current temperature, set point, and system status, allowing users to easily monitor and adjust their heating or cooling settings. The intuitive navigation buttons make programming straightforward, catering to a wide range of user needs.

The 1E50N-303 utilizes a digital electronic control system that ensures precise temperature regulation. This technology allows users to set their desired temperature with accuracy, leading to improved comfort levels and reduced energy consumption. Additionally, the thermostat includes a seven-day programmable feature, enabling users to customize their temperature settings for different days of the week. This adaptability ensures efficient energy usage, as the system can lower heating or cooling when occupants are away from home.

Another notable characteristic of the White Rodgers 1E50N-303 is its compatibility with various heating and cooling systems, including gas, oil, and electric units. This versatility makes it suitable for a wide range of applications, accommodating users with different setup requirements.

The 1E50N-303 is also equipped with a built-in filter change reminder, which promotes regular maintenance and ensures optimal system performance. By reminding users to replace or clean their filters, the thermostat helps prolong the lifespan of HVAC systems and maintain energy efficiency.

In terms of design, the White Rodgers 1E50N-303 boasts a sleek and modern appearance that fits well into any interior decor. Its compact size allows for easy installation, and it can be mounted on walls or utilized as part of a smart home system.

Overall, the White Rodgers 1E50N-303 thermostat combines essential features and advanced technologies to deliver exceptional temperature control and energy efficiency. Its user-friendly design, compatibility with various HVAC systems, and focus on maintenance make it a top choice for those looking to enhance comfort and reduce energy costs in their homes or businesses.