![Installation Checkout (cont.)](/images/new-backgrounds/40155/4015519x1.webp)
Installation Checkout (cont.)
NOTE: For more information about using the user interface and its menus, refer to the user interface Homeowners Guide.
At the main menu of the interface select SHOWER > Options > All On. This will select all connected components and purge the air from the system.
Check for leaks and make any adjustments as needed.
Verify that the water flow is sufficient for your showering needs.
6. Troubleshooting
CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining any residual water.
IMPORTANT! Turn off the power and water supply to the valve before performing any maintenance.
It is recommended that any valve maintenance should be performed by an authorized Kohler service representative.
This troubleshooting guide is for general aid only. For service and installation issues or concerns, call
Troubleshooting Table
Symptoms | Probable Cause | Recommended Action | |||
1. | Control panel is not lit. | A. | Power supply is not plugged | A. | Plug the power supply into the |
|
|
| into the outlet. |
| outlet. |
|
| B. | Power supply connection to the B. | Check power supply connections to | |
|
|
| valve may be loose or |
| the valve and reconnect if needed. |
|
|
| disconnected. |
|
|
|
| C. | Interface cable connections may | C. | Check all interface cable |
|
|
| be loose or disconnected. |
| connections, connect if needed. |
|
| D. Circuit breaker has been | D. Reset the circuit breaker. | ||
|
|
| tripped. |
|
|
|
| E. | The valve memory may require | E. | Disconnect and reconnect the |
|
|
| resetting. |
| power supply from the valve. |
|
| F. | If none of the recommended | F. | Contact your Kohler Co. authorized |
|
|
| actions for the above issues |
| service representative. |
|
|
| correct the symptom, the valve |
|
|
|
|
| or interface requires servicing. |
|
|
2. | The interface power | A. | Interface cable connections may | A. | Check all interface cable |
| indicator pulses but does |
| be loose or disconnected. |
| connections, connect if needed. |
| not turn on. |
|
|
|
|
|
| B. | If the above recommended | B. | Contact your Kohler Co. authorized |
|
|
| action does not correct the |
| service representative. |
|
|
| symptom, the interface or valve |
|
|
|
|
| requires servicing. |
|
|
3. | The interface functions | A. | Inlet/outlet fittings may be | A. | Check the inlets and outlets for |
| normally but no water |
| blocked. |
| blockage or debris. Clean the inlet |
| flows from the |
|
|
| screens. Refer to the ″Clean the |
| components. |
|
|
| Inlet Screens″ section in the Valve |
|
|
|
|
| Homeowners Guide. |
B.Hot and cold water supplies are B. Turn on the water supply to the
not turned on. |
| valve. |
C. The valve memory may require | C. | Disconnect and reconnect the |
resetting. |
| power supply from the valve. |
D. System error. | D. Check the user interface for an | |
|
| error code. Refer to the |
|
| ″Diagnostics″ section in the Digital |
|
| Interface Homeowners Guide. |
10 | Kohler Co. |