Kohler K-686, K-684, K-683, K-685 manual Troubleshooting, Installation Checkout cont

Models: K-685 K-686 K-683 K-684

1 36
Download 36 pages 32.62 Kb
Page 10
Image 10
Installation Checkout (cont.)

Installation Checkout (cont.)

NOTE: For more information about using the user interface and its menus, refer to the user interface Homeowners Guide.

At the main menu of the interface select SHOWER > Options > All On. This will select all connected components and purge the air from the system.

Check for leaks and make any adjustments as needed.

Verify that the water flow is sufficient for your showering needs.

6. Troubleshooting

CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining any residual water.

IMPORTANT! Turn off the power and water supply to the valve before performing any maintenance.

It is recommended that any valve maintenance should be performed by an authorized Kohler service representative.

This troubleshooting guide is for general aid only. For service and installation issues or concerns, call 1-800-4-KOHLER.

Troubleshooting Table

Symptoms

Probable Cause

Recommended Action

1.

Control panel is not lit.

A.

Power supply is not plugged

A.

Plug the power supply into the

 

 

 

into the outlet.

 

outlet.

 

 

B.

Power supply connection to the B.

Check power supply connections to

 

 

 

valve may be loose or

 

the valve and reconnect if needed.

 

 

 

disconnected.

 

 

 

 

C.

Interface cable connections may

C.

Check all interface cable

 

 

 

be loose or disconnected.

 

connections, connect if needed.

 

 

D. Circuit breaker has been

D. Reset the circuit breaker.

 

 

 

tripped.

 

 

 

 

E.

The valve memory may require

E.

Disconnect and reconnect the

 

 

 

resetting.

 

power supply from the valve.

 

 

F.

If none of the recommended

F.

Contact your Kohler Co. authorized

 

 

 

actions for the above issues

 

service representative.

 

 

 

correct the symptom, the valve

 

 

 

 

 

or interface requires servicing.

 

 

2.

The interface power

A.

Interface cable connections may

A.

Check all interface cable

 

indicator pulses but does

 

be loose or disconnected.

 

connections, connect if needed.

 

not turn on.

 

 

 

 

 

 

B.

If the above recommended

B.

Contact your Kohler Co. authorized

 

 

 

action does not correct the

 

service representative.

 

 

 

symptom, the interface or valve

 

 

 

 

 

requires servicing.

 

 

3.

The interface functions

A.

Inlet/outlet fittings may be

A.

Check the inlets and outlets for

 

normally but no water

 

blocked.

 

blockage or debris. Clean the inlet

 

flows from the

 

 

 

screens. Refer to the ″Clean the

 

components.

 

 

 

Inlet Screens″ section in the Valve

 

 

 

 

 

Homeowners Guide.

B.Hot and cold water supplies are B. Turn on the water supply to the

not turned on.

 

valve.

C. The valve memory may require

C.

Disconnect and reconnect the

resetting.

 

power supply from the valve.

D. System error.

D. Check the user interface for an

 

 

error code. Refer to the

 

 

″Diagnostics″ section in the Digital

 

 

Interface Homeowners Guide.

1043184-2-B

10

Kohler Co.

Page 10
Image 10