Kohler K-684, K-683, K-686, K-685 manual Troubleshooting cont, Troubleshooting Table

Models: K-685 K-686 K-683 K-684

1 36
Download 36 pages 32.62 Kb
Page 12
Image 12
Manual background

Troubleshooting (cont.)

Troubleshooting Table

Symptoms

Probable Cause

Recommended Action

 

C.

Pressure difference greater than

C.

Install pressure regulators to bring

 

 

5 psi (34.5 kPa) between the hot

 

the supplies with 5 psi (34.5 kPa)

 

 

and cold supply lines.

 

of each other.

 

D. If none of the recommended

D. Contact your Kohler Co. authorized

 

 

actions for the above issues

 

service representative.

 

 

correct the symptom, the valve

 

 

 

 

requires servicing.

 

 

10. Water leaking from the

A.

Connections are not secure.

A.

Check all connections. Make

valve.

 

 

 

adjustments as needed.

CAUTION: Risk of

B.

Seals are worn or damaged.

B.

Order a seal service pack and

personal injury or

 

 

 

replace all seals.

product damage. Turn off

C.

Internal leak.

C.

Unit requires overhaul. Contact

the main power and

 

 

 

your Kohler Co. authorized service

water supply.

 

 

 

 

 

 

representative.

 

 

 

 

11. Hot water only, the valve

A.

Hot and cold lines are reversed.

A.

Switch hot and cold water supply

shuts down.

 

 

 

connections. Verify the hot water

 

 

 

 

supply is connected to the inlet

 

 

 

 

marked ″H″ and the cold water

 

 

 

 

supply is connected to the inlet

 

 

 

 

marked ″C.″

 

 

 

 

 

1043184-2-B

12

Kohler Co.

Page 12
Image 12