TROUBLESHOOTING
1.No Power
(1)Symptom
1)It is not discharged minutely from the module.
2)Light does not come into the front LED.
(2)Check process
Is inserted a plugged | No |
|
| Plug in the power cord. | |
in power cord? |
| |
|
| |
|
|
|
Yes
Is the Line Filter | No |
| |
Connect the Cable. | |||
and Power Board Cable |
| ||
connected? |
|
| |
|
| ||
|
|
|
Is the fuse of PSU | No |
| |
Replace the Fuse. | |||
| |||
normal? |
|
|
Yes
Is it connected | No |
| |
Connect the Cable P1100. | |||
that PSU and P1100 in |
| ||
Main B/D? |
|
| |
|
|
Yes
After all cables connect is removed to PSU, the AC voltage marking is authorized on manual.
When
If there is normal status, Replace main board.
Copyright © 2008 LG Electronics. Inc. All right reserved. | - 14 - | LGE Internal Use Only |
Only for training and service purposes |
|
|