White Rodgers 1A65 installation instructions Installation Instructions, Description Precautions

Page 1

1A65/1A65W

WHITE-RODGERS

ELECTRIC-HEAT THERMOSTAT

(Single Pole)

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

The Type 1A65/1A65W Electric Heat Thermostat is de- signed for use on all types of electrical heating installa- tions such as cable heat, baseboards, wall insert heaters, etc. Its narrow operating differential and the ability of its fully exposed knob to sense both radiant heat and room air temperature make this control ideal for use on such installations.

Dial Setting: Knob may be set anywhere between 40° and 85°F by simply turning knob so that indicator on knob points to the desired setting.

DESCRIPTION

60 70

50

80

PRECAUTIONS

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction. Take care not to push or damage the knob sensing element during installation.

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system, at main fuse or circuit breaker box, until installation is complete.

All wiring must conform to local and national electrical codes and ordinances.

!WARNING

Do not use on circuits exceeding specified volt- ages. Higher voltages will damage control and could cause shock or fire hazard.

Do not use on inductive loads. Inductive (motor) loads will damage control and could cause shock or fire hazard.

 

 

SPECIFICATIONS

 

 

Switch Rating: Non-Inductive

Temperature Range: 40° to 85°F

22A (2500W) 120 VAC

Differential: 1°F

22A (5000W) 240 VAC

Switch Action: Open on rise

18A (5000W) 277 VAC

Contact Structure: SPST

If the heating equipment manufacturer has made provi- sions or recommendations for the location of this control, then follow those instructions. If not, the following sugges- tions should be observed.

1.The control should be mounted in the wall, approxi- mately five feet from the floor, as near as possible to the centre of the controlled area.

2.It should be mounted on a partitioning wall, not on an outside wall.

INSTALLATION

3.It should be mounted as far as possible from undesir- able sources of heat and cold such as:

a.Windows and doors

b.Direct rays from sun

c.Hot water or cold water pipes

d.Adjoining outside walls

WHITE-RODGERS DIVISION

 

EMERSON ELECTRIC CO.

 

9797 REAVIS RD., ST. LOUIS, MO. 63123

 

(314) 577-1300, Fax (314) 577-1517

Printed in U.S.A.

9999 HWY. 48, MARKHAM, ONT. L3P 3J3

 

(905) 475-4653, FAX (905) 475-4625

 

PART NO. 37-5427C

Replaces 37-5427B 9520