White Rodgers 1F56W-911 Specifications, Installation, Select Thermostat Location

Page 2

SPECIFICATIONS

ELECTRICAL DATA

APPLICATIONS

Switch Rating: 24 VAC (30 VAC max.)

The 1F56W-911 is designed for use with

Heating - 0.15 to 1.2 Amps

Standard heating and cooling systems

Cooling - 0 to 1.5 Amps

Electric heating and cooling systems

Switch Action: SPST - Sealed mercury switch

• Single stage heat pump systems

Anticipator Rating:

Two-transformer systems

Heating - Adjustable from 0.15 to 1.2 Amps

Electronic air cleaners

Cooling - Fixed 24 VAC

Humidifiers

THERMAL DATA

• Zone dampers

 

 

Temperature Range: 50°F to 90°F (10°C to 32°C)

This thermostat CANNOT BE USED with:

Differential: 1°F

Millivolt systems

 

Multi-stage applications

INSTALLATION

SELECT THERMOSTAT LOCATION

Proper location insures that the thermostat will provide a comfortable home temperature. Observe the following general rules when selecting a location:

1.Locate thermostat about 5 ft. above the floor.

2.Install thermostat on a partitioning wall, not on an outside wall.

3.Never expose thermostat to direct light from lamps, sun, fireplaces or any temperature radiating equip- ment.

4.Avoid locations close to windows, adjoining outside walls, or doors that lead outside.

5.Avoid locations close to air registers or in the direct path of air from them.

6.Make sure there are no pipes or duct work in that part of the wall chosen for the thermostat location.

7.Never locate thermostat in a room that is warmer or cooler than the rest of the home, such as the kitchen.

8.Avoid locations with poor air circulation, such as behind doors or in alcoves.

9.The living or dining room is normally a good location, provided there is no cooking range or refrigerator on opposite side of wall.

ROUTE WIRES TO LOCATION

NOTE

All wiring must conform with local and national electrical codes and ordinances.

1.If an old thermostat being replaced is in a satisfactory location, and the wiring appears to be in good condi- tion, use existing wiring. If in doubt, re-wire.

2.If a new location is chosen or if this is a new installa- tion, thermostat wiring must first be run to the location selected.

3.Probe for obstructions in partition before drilling 12” hole in wall at selected location. Take up quarter round and drill a small guide hole for sighting (see fig. 1). From basement, drill 34” hole in partition floor next to guide hole. In houses without basements, drill 12” hole through ceiling and into partition from above (see fig. 1).

4.Through this hole drop a light chain, or 6” chain attached to a strong cord. Snag cord in basement with hooked wire. In houses without basements, drop cord through hole in ceiling and down partitioning; snag cord at the thermostat location.

5.Attach thermostat wires to cord and pull thermostat wires through hole in wall so that 6” of wire protrudes.

12” hole for

 

thermostat wire

 

Stout cord with 6”

 

chain attached

 

Baseboard

Approximately

5 feet from floor

strip moulding

 

14” guide hole

 

for sighting

 

Quarter round

 

removed

 

34” hole in floor of partition

Hooked wire for snagging chain

Figure 1. Routing thermostat wires

2

Image 2
Contents Contents Installation InstructionsPrecautions DescriptionRoute Wires to Location SpecificationsInstallation Select Thermostat LocationAttach Thermostat to Subbase Special System ConfigurationsAttach Subbase to Wall Thermostat Wiring Operation Maintenance Factory-installed Red Jumper WireAdjusting Heat Anticipator Calibrating Thermostat