White Rodgers 1F56W-911 installation instructions Installation Instructions, Description

Page 1

1F56W-911

WHITE-RODGERSLow Voltage Heating/Cooling Thermostat

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

This low voltage thermostat is designed to provide conve- nient control of the heating/cooling system. To provide greater room comfort, the sensitive spiral bimetal is com- bined with an adjustable heating anticipator and a fixed cooling anticipator to provide maximum comfort.

90 80 70 60 50

FAN

 

AUTO

ON

DESCRIPTION

COOL

SYSTEM

 

OFF

HEAT

 

 

90

80

70

60

50

PRECAUTIONS

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor, electrician, or someone familiar with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

CONTENTS

 

Description

1

Precautions

1

Specifications

2

Installation

2

Select Thermostat Location

 

Route Wires to Location

 

Attach Subbase to Wall

 

Special System Configurations

 

Electric Heat Furnaces (Single Trans-

 

former Systems Only)

 

Two-Transformer Systems

 

Heat Pump Applications

 

Special Application Terminals

 

Attach Thermostat to Subbase

 

Operation & Maintenance

5

Adjusting Heat Anticipator

 

Calibrating Thermostat

 

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Do not short out terminals on gas valve or pri- mary control to test. Short or incorrect wiring will burn out heat anticipator and could cause per- sonal injury and/or property damage.

!WARNING

Do not use on circuits exceeding 30 volts. Higher voltage will damage control and could cause shock or fire hazard.

Thermostat installation and all components of the system shall conform to Class II circuits per the NEC code.

WHITE-RODGERS DIVISION

EMERSON ELECTRIC CO.

 

PART NO. 37-6199B

Printed in U.S.A.

Replaces 37-6199A

9797 REAVIS ROAD

ST. LOUIS, MISSOURI 63123-5398

 

0105

 

 

Image 1
Contents Precautions Installation InstructionsContents DescriptionInstallation SpecificationsRoute Wires to Location Select Thermostat LocationAttach Subbase to Wall Special System ConfigurationsAttach Thermostat to Subbase Thermostat Wiring Factory-installed Red Jumper Wire Operation MaintenanceCalibrating Thermostat Adjusting Heat Anticipator