Desa FB-60BA installation manual FBS-10BB, What to do if YOU Smell GAS

Page 1

BLUE FLAME VENT-FREE PROPANE/LP GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

FB-10BA,

FBS-10BB,

and FB-60BA

10,000 and 6,000 Btu/Hr

Thermostat and

Non-Thermostat Models

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal in- jury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installa- tion, adjustment, alteration, service, or maintenance can cause injury or property dam- age. Refer to this manual for correct installation and opera- tional procedures. For assis- tance or additional informa- tion consult a qualified in- staller, service agency, or the gas supplier.

WARNING:Thisisanunvented gas-firedheater.Itusesair(oxy- gen) from the room in which it is installed. Provisions for ad- equate combustion and venti- lation air must be provided. Refer to Air For Combustion and Ventilation on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS FBS-10BBPROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Removing Front Panel Of Heater Installing Bottom Mounting ScrewsMethods For Attaching Mounting Bracket To Wall Marking Screw LocationsTions using 9/64 drill bit Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Operating Heater Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceThermostat Control Operation For Your Safety Read Before LightingInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsService Hints Service PublicationsReplacement Parts AccessoryParts Under Warranty Parts not Under WarrantyBaltimore Electric Washer Equipment Co Dayton Hardware Parts CentralsTarantin Tank Co Heater & Fireplace Store Cans Unlimited, IncODS Pilot Assembly Illustrated Parts ListFB-10BA KEY FB-10BA Description QTY FB-60BA KEY FB-60BA Description QTY FBS-10BB KEY FBS-10BA Description QTY Warranty Information

FBS-10BB, FB-60BA specifications

The Desa FB-60BA and FBS-10BB are advanced innovations in the field of heating solutions, specifically designed to cater to a variety of residential and commercial heating needs. Both models exemplify efficiency and reliability while incorporating modern technologies to enhance user experience.

The FB-60BA is a powerful and versatile heater that ensures optimal warmth during the cold months. With a sleek design, this model seamlessly fits into any environment, providing not only functionality but also aesthetic appeal. It features an adjustable thermostat that allows users to maintain their desired temperature effortlessly. The FB-60BA also includes safety features such as an automatic shut-off mechanism in case of overheating, providing peace of mind to users.

On the other hand, the FBS-10BB is designed for portability and convenience. This compact heater is lightweight yet powerful, making it easy to move from room to room. Its fan-forced heat distribution system ensures that warmth reaches every corner of the space, making it ideal for quick heating in smaller areas. The FBS-10BB also boasts a quiet operation, allowing users to enjoy consistent heating without disruptive noise.

Both models utilize advanced heating technologies that optimize energy efficiency. They are designed to consume less energy while providing maximum heating output, which is a significant advantage for environmentally conscious consumers. This efficiency is achieved through the use of high-quality heating elements and innovative engineering that minimizes energy loss.

In terms of characteristics, the FB-60BA offers a range of wattage options, allowing users to select the level of heat that best suits their needs. Its durable construction ensures longevity, even under frequent use. The FBS-10BB, on the other hand, offers quick heat-up times, ensuring that users feel the benefits of the heater in a matter of moments.

Both models come with user-friendly controls, making them accessible to everyone, with straightforward settings for temperature adjustments and power levels. The aesthetics of these heaters, combined with their robust performance and technological advancements, make them standout choices for any heating requirement.

In conclusion, the Desa FB-60BA and FBS-10BB represent the fusion of style, safety, and energy efficiency in heating solutions. Their unique features and cutting-edge technologies cater to a wide range of consumer needs, ensuring comfort and satisfaction during cold weather conditions.