Desa FB-60BA, FBS-10BB installation manual Installation

Page 7

OWNER’S MANUAL

INSTALLATION

LOCATING HEATER

This heater is designed to be mounted on a wall.

CEILING

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary

WARNING: Maintain the mini- mum clearances shown in Figure

4. If you can, provide greater clear-

ances from floor, ceiling, and

6" Minimum From Sides of Heater

36" Minimum

heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heating source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below:

external regulator (supplied by installer, see page 9)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

test gauge connection *

sediment trap

tee joint

pipe wrench

*An CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connec- tion. The optional CSA/AGA design-certi- fied equipment shutoff valve can be pur- chased from your dealer. See Accessory, page 18.

joining wall.

WARNING: Never install the heater

in a bathroom (Models FB- 10BA and FBS-10BB only. FB- 60BA is allowed in bathroom. Check local codes.)

in a recreational vehicle

where curtains, furniture, cloth- ing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Com- bustion and Ventilation, pages 4 through 6.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving ve- hicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

Right

Side

Left

Side

2" Minimum to Top

FLOOR of Carpeting, Tile,

or Other Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

INSTALLING HEATER TO WALL

Mounting Bracket

The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

Mounting

Bracket

Figure 5 - Mounting Bracket

INSTALLING THERMOSTAT SENSING BULB -

For T-Stat Models Only

Remove clip and bulb from shipping loca- tion. Place clip and bulb into operation loca- tion (see Figure 6)

Figure 6 - Moving Thermostat Sensing Bulb

Continued

107299

7

Image 7
Contents What to do if YOU Smell GAS FBS-10BBPROPANE/LP GAS Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space Fresh AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Marking Screw Locations Installing Bottom Mounting ScrewsRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallTions using 9/64 drill bit Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections To Turn OFF GAS To Appliance Manual Lighting ProcedureOperating Heater Lighting InstructionsThermostat Control Operation For Your Safety Read Before LightingInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Service Publications SpecificationsTechnical Service Service HintsParts not Under Warranty AccessoryReplacement Parts Parts Under WarrantyHeater & Fireplace Store Cans Unlimited, Inc Parts CentralsBaltimore Electric Washer Equipment Co Dayton Hardware Tarantin Tank CoODS Pilot Assembly Illustrated Parts ListFB-10BA KEY FB-10BA Description QTY FB-60BA KEY FB-60BA Description QTY FBS-10BB KEY FBS-10BA Description QTY Warranty Information

FBS-10BB, FB-60BA specifications

The Desa FB-60BA and FBS-10BB are advanced innovations in the field of heating solutions, specifically designed to cater to a variety of residential and commercial heating needs. Both models exemplify efficiency and reliability while incorporating modern technologies to enhance user experience.

The FB-60BA is a powerful and versatile heater that ensures optimal warmth during the cold months. With a sleek design, this model seamlessly fits into any environment, providing not only functionality but also aesthetic appeal. It features an adjustable thermostat that allows users to maintain their desired temperature effortlessly. The FB-60BA also includes safety features such as an automatic shut-off mechanism in case of overheating, providing peace of mind to users.

On the other hand, the FBS-10BB is designed for portability and convenience. This compact heater is lightweight yet powerful, making it easy to move from room to room. Its fan-forced heat distribution system ensures that warmth reaches every corner of the space, making it ideal for quick heating in smaller areas. The FBS-10BB also boasts a quiet operation, allowing users to enjoy consistent heating without disruptive noise.

Both models utilize advanced heating technologies that optimize energy efficiency. They are designed to consume less energy while providing maximum heating output, which is a significant advantage for environmentally conscious consumers. This efficiency is achieved through the use of high-quality heating elements and innovative engineering that minimizes energy loss.

In terms of characteristics, the FB-60BA offers a range of wattage options, allowing users to select the level of heat that best suits their needs. Its durable construction ensures longevity, even under frequent use. The FBS-10BB, on the other hand, offers quick heat-up times, ensuring that users feel the benefits of the heater in a matter of moments.

Both models come with user-friendly controls, making them accessible to everyone, with straightforward settings for temperature adjustments and power levels. The aesthetics of these heaters, combined with their robust performance and technological advancements, make them standout choices for any heating requirement.

In conclusion, the Desa FB-60BA and FBS-10BB represent the fusion of style, safety, and energy efficiency in heating solutions. Their unique features and cutting-edge technologies cater to a wide range of consumer needs, ensuring comfort and satisfaction during cold weather conditions.