Desa FB-10BA installation manual FBS-10BB, What to do if YOU Smell GAS

Page 1

BLUE FLAME VENT-FREE PROPANE/LP GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

FB-10BA,

FBS-10BB,

and FB-60BA

10,000 and 6,000 Btu/Hr

Thermostat and

Non-Thermostat Models

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal in- jury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installa- tion, adjustment, alteration, service, or maintenance can cause injury or property dam- age. Refer to this manual for correct installation and opera- tional procedures. For assis- tance or additional informa- tion consult a qualified in- staller, service agency, or the gas supplier.

WARNING:Thisisanunvented gas-firedheater.Itusesair(oxy- gen) from the room in which it is installed. Provisions for ad- equate combustion and venti- lation air must be provided. Refer to Air For Combustion and Ventilation on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS FBS-10BBPROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Removing Front Panel Of Heater Installing Bottom Mounting ScrewsMethods For Attaching Mounting Bracket To Wall Marking Screw LocationsTions using 9/64 drill bit Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Operating Heater Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceThermostat Control Operation For Your Safety Read Before LightingInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsService Hints Service PublicationsReplacement Parts AccessoryParts Under Warranty Parts not Under WarrantyBaltimore Electric Washer Equipment Co Dayton Hardware Parts CentralsTarantin Tank Co Heater & Fireplace Store Cans Unlimited, IncODS Pilot Assembly Illustrated Parts ListFB-10BA KEY FB-10BA Description QTY FB-60BA KEY FB-60BA Description QTY FBS-10BB KEY FBS-10BA Description QTY Warranty Information

FB-10BA specifications

Desa FB-10BA is a remarkable addition to the world of portable heating solutions, designed to deliver efficient warmth in a variety of settings. Standing out in the market for its user-friendly features and robust technology, it’s a popular choice among homeowners and professionals alike.

One of the main features of the Desa FB-10BA is its impressive heating capacity. It can efficiently warm spaces of up to 1,000 square feet, making it suitable for large garages, workshops, or any sizeable room. The powerful output of 10,000 BTU ensures that users can achieve the desired temperature quickly and maintain it consistently throughout colder months.

Incorporating advanced ceramic technology, the FB-10BA utilizes a ceramic heat exchanger that promotes quick and effective heating. This design not only enhances the performance but also contributes to energy efficiency. Consumers benefit from reduced energy consumption while still enjoying full functionality, helping to save on heating costs.

The unit operates on propane, a clean-burning fuel source that minimizes environmental impact compared to traditional fuels. Its portability is another significant characteristic; the FB-10BA is equipped with a rugged handle and a lightweight design, enabling easy transport from one location to another.

Safety features are paramount in the design of the Desa FB-10BA. The built-in automatic shut-off mechanism activates in case of overheating or when the unit is tipped over, providing peace of mind for users. Additionally, it comes with an adjustable thermostat that allows for precise temperature control, enabling users to customize their heating experience according to their needs.

The flexibility of the FB-10BA is further highlighted by its ability to run both indoors and outdoors, making it a versatile option for camping trips, outdoor gatherings, or simply heating up a chilly garage or workshop. The durable construction ensures that it can withstand the rigors of different environments, offering longevity and reliability.

In summary, the Desa FB-10BA combines efficiency, portability, and safety in a well-designed heating solution. Its powerful heating capacity, advanced ceramic technology, and user-friendly features make it a valuable asset for anyone looking to stay warm during the colder months while enjoying the advantages of modern heating technologies.