Desa FB-10BA Ventilation AIR, Ventilation Air From Inside Building, Ventilation Air From Outdoors

Page 6

PROPANE/LP GAS HEATER

FRESH AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

6

105565

Image 6
Contents FBS-10BB What to do if YOU Smell GASSafety Information PROPANE/LP GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction Fresh AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceFresh AIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Methods For Attaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsRemoving Front Panel Of Heater Marking Screw LocationsConnecting to GAS Supply Tions using 9/64 drill bitPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Lighting Instructions Manual Lighting ProcedureOperating Heater To Turn OFF GAS To ApplianceFor Your Safety Read Before Lighting Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Service Hints SpecificationsTechnical Service Service PublicationsParts Under Warranty AccessoryReplacement Parts Parts not Under WarrantyTarantin Tank Co Parts CentralsBaltimore Electric Washer Equipment Co Dayton Hardware Heater & Fireplace Store Cans Unlimited, IncIllustrated Parts List ODS Pilot AssemblyFB-10BA KEY FB-10BA Description QTY FB-60BA KEY FB-60BA Description QTY FBS-10BB KEY FBS-10BA Description QTY Warranty Information

FB-10BA specifications

Desa FB-10BA is a remarkable addition to the world of portable heating solutions, designed to deliver efficient warmth in a variety of settings. Standing out in the market for its user-friendly features and robust technology, it’s a popular choice among homeowners and professionals alike.

One of the main features of the Desa FB-10BA is its impressive heating capacity. It can efficiently warm spaces of up to 1,000 square feet, making it suitable for large garages, workshops, or any sizeable room. The powerful output of 10,000 BTU ensures that users can achieve the desired temperature quickly and maintain it consistently throughout colder months.

Incorporating advanced ceramic technology, the FB-10BA utilizes a ceramic heat exchanger that promotes quick and effective heating. This design not only enhances the performance but also contributes to energy efficiency. Consumers benefit from reduced energy consumption while still enjoying full functionality, helping to save on heating costs.

The unit operates on propane, a clean-burning fuel source that minimizes environmental impact compared to traditional fuels. Its portability is another significant characteristic; the FB-10BA is equipped with a rugged handle and a lightweight design, enabling easy transport from one location to another.

Safety features are paramount in the design of the Desa FB-10BA. The built-in automatic shut-off mechanism activates in case of overheating or when the unit is tipped over, providing peace of mind for users. Additionally, it comes with an adjustable thermostat that allows for precise temperature control, enabling users to customize their heating experience according to their needs.

The flexibility of the FB-10BA is further highlighted by its ability to run both indoors and outdoors, making it a versatile option for camping trips, outdoor gatherings, or simply heating up a chilly garage or workshop. The durable construction ensures that it can withstand the rigors of different environments, offering longevity and reliability.

In summary, the Desa FB-10BA combines efficiency, portability, and safety in a well-designed heating solution. Its powerful heating capacity, advanced ceramic technology, and user-friendly features make it a valuable asset for anyone looking to stay warm during the colder months while enjoying the advantages of modern heating technologies.