Desa VF-24N-BTB, VF-18P-PDG installation manual Product Identification, Remote Ready Models

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire depart- ment

4.This heater shall not be installed in a bedroom or bathroom, unless installed as a vented appliance. See Installing Damper Clamp Accessory for Vented Operation, page 10.

5.Before installing in a solid fuel burning fireplace, the chim- ney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, repair flue damper before operating heater.

6.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

7.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 18.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls and furniture.

9.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if enough fresh air is not available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 19 through 21.

10.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this heater to cook food or burn paper or other ob- jects.

12.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

13.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger).

14.Turn heater off and let cool before servicing, installing, or repairing. Make sure the selector switch is in the OFF position (Remote-Ready Models Only). Only a qualified service person should install, service, or repair heater.

15.Make sure the selector switch is in the OFF position when you are away from home for long periods of time (Remote-Ready Models Only).

16.Remote-Ready heaters do not to be connected to any external electrical source.

17.Operating heater above elevations of 4,500 feet may cause pilot outage.

18.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity (propane/LP units only).

19.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Log Set

 

 

 

 

Lava Rock

Piezo

Control Knobs

Ignitor

 

Log Scraps

Chassis Assembly

 

 

REMOTE READY MODELS

Log Set

 

 

 

 

Lava Rock

Piezo

 

 

Ignitor

 

 

Remote

 

Log Scraps

 

Remote

Control

 

 

Reciever

 

 

Control Knobs

Chassis Assembly

 

 

 

REMOTE CONTROLLED MODELS

Figure 1 - Product Identification

For more information, visit www.desatech.com

111826-01F

Image 3
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsRemote Ready Models Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation and Clearances for VENT-FREE OperationCheck GAS Type Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Assembly Installation Items NeededConnecting to GAS Supply Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Checking Gas Joints propane/LP only For Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure Remote Control OperationTo Turn OFF GAS to Appliance Ghrctb Series Operation Thermostat Control OperationInspecting Burners Pilot Flame PatternBurner Flame Pattern Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Observed Problem Possible Cause VF-18N-PDG/VF-18N-BTB SpecificationsReplacement Parts Wiring DiagramService Hints Technical ServiceIllustrated Parts Breakdown Log sets and mounting plates are ordered as an assemblyVF-24N-PDG, VF-24P-PDG, VF-24N-BTB, VF-24P-BTB Parts List Parts ListAccessories This page Intentionally Left Blank Owners Registration Form Postage Required 111826-01F Warranty Information