Desa RCP25 owner manual Specifications

Page 14

SPECIFICATIONS

Input Rating

52.223 kJ/Hr (49,500 BTU/Hr)

Fuel

Propane Vapor Only

Fuel Consumption

 

Liters/Hour (Gallons/Hour)

1.9 (0.5)

Kilos/Hour (Pounds/Hour)

1.04 (2.3)

Supply Pressure To Regulator

 

Minimum (for purposes

69 kPa (10 psi)

of input adjustment)

 

Maximum

Tank Pressure or 1379 kPa (200 psi)

Regulator Outlet Pressure

45.7 cm (18") WC

Manifold Pressure

42 cm (16.5") WC

Motor

3100 RPM

Electric Input

120 volt/60 hertz

Amperage

3 amps

Ignition

Manual, Piezo

Weight

 

Heater

7 kg (15.5 pounds)

Shipping

7.7 kg (17 pounds)

Size - L x W x H

47 cm x 20 cm x 33 cm

 

(18.5" x 7.7" x 12.8")

Temperature Range for Heater Operation

-29°C to 29°C* (-20° F to 85° F*)

*When running heater in temperatures above 29°C (85° F), high internal tempera- tures may cause thermal limit device to shut down heater.

WIRING DIAGRAM

Electrode Piezo Ignitor

Motor

Green

Thermo-

couple

8 7

Red 6 5

Red 4 3

2 1

Relay

Gas

Valve

 

 

Thermal

 

 

Blue

Blue

Switch

Blue

Black

T

 

 

 

Connector

White

 

White

 

Green

White

 

 

 

 

 

 

 

Yellow

Blue

Start

 

Yellow

Switch

 

Yellow

 

 

 

Terminal

Board

14

Figure 14 - Connection Diagram

101489

Image 14
Contents Canadian Propane Construction Heater Contents Safety Information Safety Information Unpacking Product IdentificationPropane TheoryOperation SupplyInstallation Regulator PositionInstallation Ventilation Operation To Start HeaterTo Stop Heater To Restart HeaterStorage Maintenance Disconnect heater from propane supply tanksObserved Fault Possible Cause Remedy TROUBLE- ShootingService Procedures MotorFan MotorCausing severe burns IgnitorSpecifications Parts Under Warranty AccessoriesTechnical Service Service Publications Replacement Parts Parts Not Under Warranty101489 101489 Warranty and Repair Service Limited WarrantyAppareils Table DES Matières Dos du manuelAvertissements Suite DÉ Ballage Nomenclature DES PIÈ CESEN Propane Principes DENctionnement Avertissement Ventilation Fonctionnement Mise en marche de l’appareilPour arrê ter l’appareil de chauffage Pour remettre l’appareil en marcheRemisage Entretien Dé brancher l’appareil du ou des ré servoirs de propaneDÉ Pannage Anomalie Observé E Cause Probable Remè DEAnomalie Observé E Cause Probable Procé Dure D’ENTRETIEN MoteurMoteur suite Dé pose ou fixation du ventilateur sur l’arbre du moteurVentilateur AllumeurAllumeur suite Retrait de la vis de montage et de l’allumeurSPÉ Cifications Piè ces sous garantie AccessoiresService Technique Publications Techniques Piè ces qui ne sont pas sous garantieGarantie ET Service DE RÉ Paration Garantie Limité E