INSTALLATION
Continued
VENTILATION
OPERATION
4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly,
5.Check all connections for leaks.
WARNING
Never use an open flame to check for a leak. Apply a mix- ture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
6. Close propane supply valve.
WARNING
Provide at least a 0.14 m2
IMPORTANT: Provide extra fresh air if more heaters are being used.
WARNING
Review and understand the warnings in the Safety Informa- tion section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.
To Start Heater
1.Follow all installation, ventilation, and safety information.
2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.
3.Plug power cord of heater into a
Extension Cord Wire Size Requirements
Up to 15 meters (50 feet) long, use 18 AWG rated cord.
15.5 to 30.5 meters (51 to 100 feet) long, use 16 AWG rated cord.
31 to 61 meters (101 to 200 feet) long, use 14 AWG rated cord.
4.Plug extension cord into a 120 volt/60 hertz,
Continued
7
101489