Empire Comfort Systems VFDR24LB, VFDR30LB, VFDR18LB installation instructions Cleaning and Servicing

Page 18

CLEANING AND SERVICING

Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting.

TURN OFF HEATER AND ALLOW TO COOL BEFORE CLEANING.

Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Refer to manual for correct log placement.

PERIODIC CLEANING – Refer to parts diagram for location of items discussed below.

Do not use cleaning fluid to clean logs or any part of heater.

Logs - brush with soft bristle brush or vacuum with brush attachment.

Remove loose particles and dust from the burner, controls and grate.

Inspect and clean burner air intake hole. Remove lint or particles with brush. Failure to keep air intake hole clean will result in sooting and poor combustion.

ANNUALCLEANING/INSPECTION – Refer to parts diagram for location of items discussed below.

Inspect and clean burner air intake hole. Remove lint or particles with vacuum or brush. Failure to keep air intake hole clean will result in sooting and poor combustion.

Inspect and clean all burner ports.

Inspect ODS pilot for operation and accumulation of lint at air intake holes.

Verify flame pattern and log placement for proper operation.

Verify smooth and responsive ignition of main burner.

Page 18

21565-3-0906

Image 18
Contents Installation Instructions Table of Contents Important Safety Information Carbon Monoxide Poisoning MAY Lead to DeathSafety Information for Users of LP-GAS LP-GAS Warning OdorProduct Specifications Well Head Gas InstallationsAccessories IntroductionsMake sure you have received all parts General InformationBefore you get started High AltitudeClearances Unusually Tight ConstructionGlass Doors Mantel Clearances Without Hood Figure Installing as a Vented ApplianceSidewall & Ceiling Clearances Figure Mantel Clearances with Hood FigureCombustible Material Fireplace PreparationInstalling AS a Vented Appliance Before Fully Installing the ApplianceInstalling Damper Clamp Figure GAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterVFDR18,24 LOG Placement 5 LOG SET Ember Material Placement on BurnerVFDR30 LOG Placement 7 LOG SET Ember Material Placement on BurnerOperation INSTRUCTIONS/FLAME Appearance Millivolt FigureRemote Receiver WiringCheck System Operation Millivolt SystemVFDR18,24,30LB Lighting Instructions What to do if YOU Smell GASPilot Flame Characteristics Correct Pilot Flame Pattern Incorrect Pilot Flame PatternCleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningAppliance produces unwanted odors Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance shuts off during use. Pilot stays onParts List Index Part Numbers Description VFDR18LB VFDR24LB VFDR30LBHOW to Order Repair Parts Parts ViewService Notes Service Notes

VFDR18LB, VFDR24LB, VFDR30LB specifications

Empire Comfort Systems specializes in high-quality heating solutions, and their VFDR series, which includes the VFDR30LB, VFDR24LB, and VFDR18LB models, showcases the company’s commitment to innovation and efficiency. These vent-free gas log fireplaces are designed to provide warmth and ambiance, making them perfect for any living space.

One of the standout features of the VFDR series is the vent-free design, which allows for easy installation. These fireplaces do not require a chimney or flue, providing flexibility in placement without the need for extensive renovations. This vent-free feature enables the fireplaces to operate efficiently while releasing warmth directly into the room, making them an excellent choice for standing out in compact spaces.

The VFDR models are equipped with advanced technology, including a patented dual burner system. This unique burner design allows for a more realistic flame appearance while maximizing heat output. The result is a mesmerizing fire that enhances the ambiance of any setting. Additionally, the variable flame height control lets users adjust the intensity of the fire, providing customizability according to individual preferences.

When it comes to safety, Empire Comfort Systems has integrated several features in the VFDR series. The fireplaces include an Oxygen Depletion Sensor (ODS), which automatically turns off the burner if the oxygen levels in the room drop too low, ensuring peace of mind while using the appliance. Furthermore, the appliances are built with a safety pilot light, reinforcing their reliability and user safety.

Each model in the VFDR series comes with different heat output capabilities. The VFDR30LB provides up to 30,000 BTUs, making it suitable for larger spaces, while the VFDR24LB and VFDR18LB cater to medium and smaller areas with outputs of 24,000 and 18,000 BTUs, respectively. This versatility allows homeowners to select the perfect model based on their heating needs.

The VFDR series is also visually appealing, featuring a realistic log set and a stylish finish that complements a variety of interior designs. With a wide range of decorative options available, consumers can customize their fireplace to enhance their home’s aesthetic.

In summary, the Empire Comfort Systems VFDR30LB, VFDR24LB, and VFDR18LB models are an exceptional choice for anyone seeking a reliable, efficient, and stylish heating solution. Their vent-free design, innovative burner system, safety features, and aesthetic appeal make them standouts in the market. Whether for a cozy living room or an inviting den, these fireplaces provide the perfect combination of functionality and warmth.