III. Step 3

Turn off the electrical power supply to the unit.

IV. Step 4

Remove the front access panel.

V. Step 5

Move the selector switch on the internal gas valve to the OFF position.

VI. Step 6

Replace the front access panel.

VII. Step 7

Restore electrical power to the unit and set system switch to COOL to ensure operation of the cooling system during the cooling season.

ROUTINE MAINTENANCE

All routine maintenance should be handled by skilled, expe- rienced personnel. Your dealer can help you establish a stand- ard procedure.

For your safety, keep the unit area clear and free of combus- tible materials, gasoline, and other ¯ammable liquids and vapors.

To assure proper functioning of the unit, ¯ow of combustion and ventilating air must not be obstructed from reaching the unit. Clearance of at least 30 in. is required on all sides ex- cept the duct side.

MAINTENANCE AND CARE FOR THE

EQUIPMENT OWNER

Before proceeding with those things you might want to main- tain yourself, please carefully consider the following:

WARNING:

1.TURN OFF GAS SUPPLY AND ELECTRICAL POWER TO YOUR UNIT BEFORE SERVICING OR PERFORMING MAINTENANCE.

2.Do not turn off electrical power to this unit without ®rst turning off the gas supply.

3.When removing access panels or performing main- tenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be ex- tremely careful when handling parts or reaching into the unit.

I.Air Filters

Air ®lter(s) should be checked at least every 3 or 4 weeks and changed or cleaned whenever it becomes dirty. Dirty ®lters produce excessive stress on the blower motor and can cause the motor to overheat and shut down. Table 1 indicates the correct ®lter size for your unit. Refer to Fig. 5 to access the ®lter(s).

To replace or inspect ®lter(s) (or accessory ®lter rack when supplied):

1.Remove the ®lter access panel using a 5¤16-in. nut driver.

2.Remove the ®lter(s) by pulling the ®lter(s) out of the unit. If the ®lter(s) is dirty, clean or replace with new one.

When installing the new ®lter(s), note the direction of the air- ¯ow arrows on the ®lter frame.

Fig. 2 Ð Gas Heating/Electric Cooling Unit

(Internal View)

If you have difficulty in locating your air ®lter(s), or if you have questions concerning proper ®lter maintenance, con- tact your dealer for instructions. When replacing ®lters, al- ways use the same size and type of ®lter that was supplied originally by the installer.

Table 1 Ð Indoor-Air Filter Data*

UNIT SIZE

FILTER SIZE

582A018-030

20x24

582A036-042

20x24

582A048-060

24x30

583A024-030

20x20

583A036

20x24

583A042-060

24x30

*For ®lter grille installations only.

WARNING: Never operate your unit without ®lters in place. Failure to heed this warning may result in dam- age to the blower motor and/or compressor. An accumu- lation of dust and lint on internal parts of your unit can cause loss of ef®ciency and, in some cases, ®re.

II. Heat Exchanger

To ensure dependable and efficient heating operation, the heat exchanger should be checked by a quali®ed maintenance per- son before each heating season, and cleaned when necessary. This checkout should not be attempted by anyone not having the required expertise and equipment to properly do the job. Checking and/or cleaning the heat exchanger involves remov- ing the gas controls assembly and the ¯ue collector box cover and, when completed, reinstalling the gas controls assembly for proper operation. Also, the ¯ue collector box cover must be replaced correctly so that a proper seal is maintained. Con- tact your dealer for the required periodic maintenance.

III. Fans and Fan Motor

Periodically check the condition of fan wheels and hous- ings and fan-motor shaft bearings. No lubrication of condenser- or evaporator-fan bearings or motors is required or recommended.

IV. Evaporator and Condenser Coils

Cleaning of the coils should only be done by quali®ed service personnel. Contact your dealer for the required annual maintenance.

Ð3Ð

Image 3
Contents Users information manual To Shut Unit OFF To Light UnitMaintenance and Care for Equipment Owner Routine MaintenanceCondensate Drain VI. CompressorVII. Condenser Fan To Light Unit To Shut Unit Off XI. Unit Panels Regular Dealer MaintenanceIX. Refrigerant Circuit Combustion Area and Vent SystemCase of Trouble
Related manuals
Manual 28 pages 39.87 Kb

583A specifications

The Bryant 583A is a cutting-edge gas furnace designed for both efficiency and comfort, making it an ideal heating solution for residential applications. This model is particularly known for its exceptional performance and innovative technology, resulting in lower energy bills and a more consistent indoor environment.

One of the standout features of the Bryant 583A is its high-efficiency operation, boasting an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%. This means that a significant portion of the fuel consumed is converted into usable heat, making it an environmentally friendly choice that reduces energy waste. The design employs a two-stage heating operation, which allows the furnace to adjust its output according to the heating demands of the home, providing balanced warmth while minimizing energy consumption.

Built with advanced technology, the Bryant 583A includes a variable-speed blower motor that enhances comfort by distributing heated air more evenly throughout the home. This feature not only improves air circulation but also promotes quieter operation compared to standard single-speed blowers. The intelligent control system of the furnace permits compatibility with smart thermostats, which further enhances energy efficiency and user convenience.

Another notable characteristic of the Bryant 583A is its durability. Constructed with high-quality materials, this furnace is designed to withstand the rigors of continuous operation and to provide reliable service throughout its lifespan. Additionally, it features a heavy-duty heat exchanger that ensures optimal heat transfer while reducing the risk of breakdowns.

The Bryant 583A also prioritizes safety with features such as an automatic shut-off, which activates in the event of a malfunction, protecting both the system and the home. Additionally, its compact design allows for easy installation in a variety of spaces, making it a versatile choice for different home layouts.

In summary, the Bryant 583A is a remarkable gas furnace that combines high-efficiency performance, cutting-edge technology, and reliability. With its two-stage heating operation, variable-speed blower motor, and robust safety features, it caters to homeowners seeking both comfort and cost savings during the colder months. As a trusted name in heating solutions, Bryant continues to lead the way in delivering products that enhance home comfort while prioritizing energy efficiency and durability.