VIII. Electrical Controls and Wiring

Electrical controls are difficult to check without proper in- strumentation; therefore, if there are any discrepancies in the operating cycle, contact your dealer and request service.

IX. Refrigerant Circuit

The refrigerant circuit is difficult to check for leaks without the proper equipment; therefore, if inadequate cooling is sus- pected, contact your local dealer for service.

X. Combustion Area and Vent System

The combustion area and vent system should be inspected visually before each heating season. The normal accumula- tion of dirt, soot, rust, and scale can result in loss of effi- ciency and improper performance if allowed to build up.

CAUTION: If your unit makes an especially loud noise when the main burners are ignited, shut down the heat- ing section and call your dealer.

Proceed as follows to inspect the combustion area and power- venting system of your unit.

1.Turn off electrical power and gas supply to your unit.

2.Remove burner access panel. (See Fig. 1.)

3.Using a ¯ashlight, carefully inspect the burner areas for dirt, soot, rust, or scale. See Fig. 2.

CAUTION: If dirt, soot, rust, or scale accumulations are found, call your dealer and do not operate your heat- ing section.

4.When you have completed your inspection, follow the start-up procedures in this manual to restore your unit to operation.

5.Observe unit heating operation.

WARNING: Components in heat section may be hot after unit has been started up. When observing ¯ame, be careful not to get close to or touch heating compo- nents or serious personal injury may result.

Watch the burner ¯ame to see if it is bright blue. If you observe a suspected malfunction or if the burner ¯ames are not bright blue, call your dealer.

6. Replace burner access panel.

XI. Unit Panels

After performing any maintenance or service on the unit, be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit air¯ow pattern.

REGULAR DEALER MAINTENANCE

In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (pref- erably each year, but at least every other year) should in- clude the following:

1.Inspection of all ¯ue product passages Ð including the burners, heat exchanger, and ¯ue collector box.

2.Inspection of all combustion- and ventilation-air pas- sages and openings.

3.Close inspection of all gas pipes leading to and inside of your unit.

4.Inspection and, if required, cleaning of the condenser and evaporator coils.

5.Inspection and, if required, cleaning of the evaporator drain pan.

6.Inspection and cleaning of blower wheel housing and motor.

7.Inspection of all supply-air and return-air ducts for leaks, obstructions, and insulation integrity. Any problems found should be resolved at this time.

8.Inspection of the unit base to ensure that no cracks, gaps, etc., exist which may cause a hazardous condition.

9.Inspection of the unit casing for signs of deterioration.

10.Inspection of all electrical wiring and components to assure proper connection.

11.Inspection for leaks in the refrigerant circuit. Pressure- check to determine appropriate refrigerant charge.

12.Inspection of compressor oil level.

13.Operational check of the unit to determine working con- ditions. Repair or adjustment should be made at this time.

Your servicing dealer may offer an economical service con- tract that covers seasonal inspections. Ask for further details.

Complete service instructions can be found in the unit Installation, Start-Up and Service Instructions.

WARRANTIES

Units 582A and 583A have warranties located at the back of this book. Be sure to read the warranty carefully to deter- mine the coverage for your unit.

Ð7Ð

Image 7
Contents Users information manual To Shut Unit OFF To Light UnitMaintenance and Care for Equipment Owner Routine MaintenanceVI. Compressor Condensate DrainVII. Condenser Fan To Light Unit To Shut Unit Off XI. Unit Panels Regular Dealer MaintenanceIX. Refrigerant Circuit Combustion Area and Vent SystemCase of Trouble
Related manuals
Manual 28 pages 39.87 Kb

583A specifications

The Bryant 583A is a cutting-edge gas furnace designed for both efficiency and comfort, making it an ideal heating solution for residential applications. This model is particularly known for its exceptional performance and innovative technology, resulting in lower energy bills and a more consistent indoor environment.

One of the standout features of the Bryant 583A is its high-efficiency operation, boasting an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%. This means that a significant portion of the fuel consumed is converted into usable heat, making it an environmentally friendly choice that reduces energy waste. The design employs a two-stage heating operation, which allows the furnace to adjust its output according to the heating demands of the home, providing balanced warmth while minimizing energy consumption.

Built with advanced technology, the Bryant 583A includes a variable-speed blower motor that enhances comfort by distributing heated air more evenly throughout the home. This feature not only improves air circulation but also promotes quieter operation compared to standard single-speed blowers. The intelligent control system of the furnace permits compatibility with smart thermostats, which further enhances energy efficiency and user convenience.

Another notable characteristic of the Bryant 583A is its durability. Constructed with high-quality materials, this furnace is designed to withstand the rigors of continuous operation and to provide reliable service throughout its lifespan. Additionally, it features a heavy-duty heat exchanger that ensures optimal heat transfer while reducing the risk of breakdowns.

The Bryant 583A also prioritizes safety with features such as an automatic shut-off, which activates in the event of a malfunction, protecting both the system and the home. Additionally, its compact design allows for easy installation in a variety of spaces, making it a versatile choice for different home layouts.

In summary, the Bryant 583A is a remarkable gas furnace that combines high-efficiency performance, cutting-edge technology, and reliability. With its two-stage heating operation, variable-speed blower motor, and robust safety features, it caters to homeowners seeking both comfort and cost savings during the colder months. As a trusted name in heating solutions, Bryant continues to lead the way in delivering products that enhance home comfort while prioritizing energy efficiency and durability.