Armstrong World Industries EHU-704 Monitoring Current, Monitoring % Power, Manual Drain Mode

Page 19

Monitoring Current:

While the unit is filling, the current should increase. As the current approaches the maximum rating of the unit, it increases more slowly, especially in higher capacity units. With the tank on, and the fill and drain circuits idle, the current should fall slowly. When the unit is draining, the current should decrease at a moderate rate.

Monitoring % Power:

The percentage power equates to the percentage of maximum steam output. The percentage power reading will increase and decrease proportionally to the current draw. Overcurrent protection circuitry starts initiating drain cycles as the % power reading approaches 110%. The overcurrent failure routine is initiated at about 120%.

Automatic Drain Operation:

The microcontroller will energize the drain valve at the beginning of the fill cycle to reduce the conduc- tivity and mineral build-up in the tank. It will vary in drain duration to adjust for changes in water quali- ty, demand history, and steam output.

Manual Drain Mode:

If the manual drain button is pushed while the tank circuit is energized, the fill valve will also open to temper the drain water. If the tank is off, only the drain valve will open.

19

Image 19
Contents Installation and Maintenance Metal Tools Away from These Areas Table of Contents Site Selection PRE-INSTALLATIONCheck Shipment Check Local CodesWater Total Important Please observe the following InstallationElectrical Service Wiring Mounting the HumidifierConnect Drain Water Fill SupplyPressure in duct is high, see Figure Control Humidistat Control WiringWall Mounted Control Humidistat 10 FtDuct Mounted Control Humidistat Airflow SwitchHigh Limit Duct Humidistat Generator a Audible AlarmInstrument Panel Before Turning on the Power START-UP Procedure for Armstrong Series EHU-700 HumidifiersTurn on Power AT the Circuit Breaker Page Page Troubleshooting Guide Tank Contactor Operation Operational GuidelinesMonitoring Stat Demand Automatic Drain Operation Monitoring % PowerManual Drain Mode Monitoring CurrentC00 Normal Operation C01 High Water EHU-700 DiagnosticsDiagnostic Display Messages C02 Tank Needs CleaningC07 Overcurrent Failure C04 High Limit CircuitC05 Drain System Failure C06 Fill System FailureC09 I/O Diagnostics Water Quality and Treatment for EHU Series Humidifiers When Water Conductivity is TOO LOWGeneral Remedies When Water Conductivity is TOO HighResults RemedySteam Generator Parts Valves and Mechanical Parts Electrical Parts EHU-700 Parts List Month to 1 Year MaintenanceRecommended Maintenance Schedule To 2 Days After Start UP Steam Generator MaintenanceTank Removal and Replacement ALL Models Steam Generator Chemical Cleaning Procedure Page Models EHU-703 and 704, Single and Three Phase Tank DISASSEMBLY, CLEANING, and Electrode ReplacementFill and Drain System Repair Model EHU-701, Single and Three PhaseDrain System Failure Fill System Failure Sensor Failure Protection Autocal ProcedureSpecifications Humidistat DataSensor Characteristics DimensionsAIR Supply High Limit Humidity Sensor Humidity SET Point Reset by Outside TemperatureHumidistat model number H270-69-13-10-31 Application ExampleDimensional Information

EHU-701, EHU-700 Series, EHU-704, EHU-703 specifications

Armstrong World Industries has long been a leader in the ceiling and wall solutions industry, and its EHU-700 Series exemplifies the commitment to innovation and quality. The EHU-700 Series, which includes models such as the EHU-703, EHU-704, and EHU-701, is designed for a variety of commercial applications, combining aesthetic appeal with superior performance characteristics.

One of the key features of the EHU-700 Series is its exceptional acoustic control. The panels are crafted using advanced sound-absorbing materials that effectively reduce noise levels in busy environments. This makes them ideal for areas such as offices, schools, and healthcare facilities, where quietness can significantly enhance productivity and comfort. The EHU-700 Series has been rigorously tested and certified to meet stringent industry standards, ensuring its effectiveness in noise reduction.

Additionally, these ceiling panels are designed with durability in mind. Made from high-quality components, the EHU-700 Series is resistant to moisture and staining, making them suitable for spaces exposed to humidity, such as kitchens and restrooms. This resilience ensures that the panels maintain their aesthetic appeal over time, reducing maintenance costs for facility managers.

The EHU-700 Series also incorporates Armstrong's innovative technologies to enhance ease of installation and flexibility. The panels feature a lightweight design, allowing for straightforward handling and installation. Compatibility with various grid systems ensures that the EHU-700 Series can be easily integrated into existing architectural designs, providing a seamless finish.

Another significant aspect of the EHU-700 Series is its commitment to sustainability. Armstrong World Industries emphasizes eco-friendly manufacturing processes and materials, allowing architects and builders to achieve green building certifications, such as LEED. The use of recyclable materials in the panel composition reflects a commitment to reducing the environmental footprint.

In summary, the EHU-700 Series, including the EHU-703, EHU-704, and EHU-701 models, showcases Armstrong World Industries' dedication to quality and innovation. With unparalleled acoustic performance, durability, installation convenience, and sustainability, these ceiling panels are ideal for a wide array of commercial environments, proving to be a valuable investment for modern architectural needs. Their combination of functionality and design ensures that they meet the demands of today's dynamic spaces.