Aprilaire 448 owner manual Inspection and Service Instructions

Page 11

Inspection and Service Instructions

IN-LINE STRAINER

OUTLET COMPRESSION NUT

ORIFICE

SOLENOID

VALVE

INLET

INLET COMPRESSION NUT

1.Disconnect electrical power to the furnace and shut off water supply.

2.Disconnect the water line at the inlet compression nut.

3.Remove the in-line strainer from inside the inlet side of the valve by using a small nail or wire.

4.Flush the in-line strainer clean or replace with a new strainer, Service Department, Part No. 4004.

5.Replace the in-line strainer and reconnect the inlet water line (Double Wrench To Prevent Leaking).

6.Disconnect the water line at the outlet compression nut.

7.Remove the orifice from the copper or plastic tube and make sure this small opening is unplugged.

8.Replace the orifice and reconnect the outlet water line (Double Wrench To Prevent Leaking).

9.Turn on water supply and reconnect electrical power to the furnace.

- 9 -

Image 11
Contents Automatic Humidifier Introduction Principle of Operation Page Operation Guide Automatic Mode Manual Mode-see pgFigure a % Relative Humidity Guide Outdoor Temperature ºF Setting Dial Figure B III. Effect of Water Characteristics IV. Annual Maintenance Inspection and Service Instructions For ModelMaintenance Instructions For Models Reservoir Pump Sections Models Model Model Limited Warranty Aprilaire Fresh Air Exchangers Electronic Thermostats Aprilaire Zone Control SystemsService and Water Panel Replacement Record DP #10005406