Aprilaire 112, 350, 360, 760, 445, 440, 560, 220 Manual Humidistat Automatic Humidifier Control see pg

Page 7

Manual Humidistat:

(Automatic Humidifier Control – see pg 3)

Your new Aprilaire Humidifier is controlled by a humidistat installed either in the living area or in the cold air return. It is important to anticipate a drop in outdoor temperature and reduce the setting accordingly to avoid excessive condensation. For example, with an outdoor temperature of 20° the correct setting will be 35% relative humidity. If the temperature is expected to fall to 0° that evening, then merely reduce the setting to 25% several hours prior to the temperature change.

The recommended settings on the humidistat are based on years of research (see table 3) and experience as to what is best for the average home. These settings represent a compromise between RH levels that would be most desirable for comfort reasons and humidity levels that are suitable for protection of your home. For example, a wintertime indoor RH of 50% may be considered ideal, but unfortunately, it probably would result in damage to your home. Observance of the recommended RH levels on your humidistat, therefore, is an important safeguard. Condensation of water on inside windows in the form of fogging or frost is usually an indication of too high relative humidities. This same condensation can take place in other areas in your home with the possibility of damage resulting.

(Table 3) Outdoor-Indoor Relative Humidity

Outside Temperature

Recommended RH

+40°

45%

+30°

40%

+20°

35%

+10°

30%

25%

–10°

20%

–20°

15%

 

 

The humidistat is a precision instrument that can be used to determine the RH accurately in your home during the winter. Turn the dial to the lower setting, then reverse the dial direction slowly until a “click” is heard. At this point, read the RH on the dial. This will be very close to the actual RH in your home.

- 5 -

Image 7
Contents Maintenance Instructions Table of ContentsIntroduction Your Humidifier Page Operation Guide Automatic Humidifier Control Manual humidistat-see pg% Relative Humidity Guide Outdoor Temperature ºF Setting DialOutdoor-Indoor Relative Humidity Manual Humidistat Automatic Humidifier Control see pgAdditional Information III. Effect of Water CharacteristicsAnnual Summer Shutdown IV. Annual MaintenanceInspection Service Instructions VI. Periodic Preventative MaintenanceAprilaire Humidifier Models ForModels Aprilaire Humidifier Model Maintenance Instructions Inlet Grille 110-112 Model Limited Warranty Aprilaire Fresh Air Exchangers Electronic Thermostats Aprilaire Zone Control SystemsService and Water Panel Replacement Record
Related manuals
Manual 11 pages 28.78 Kb