Aprilaire 62 Relative Humidity Guide, Outdoor Temperature F, 10F 20F 30F 40F, Condition Solution

Page 5

ADDITIONAL INFORMATION

Your humidifier is a precision system that will accurately maintain the humidity in your home. For every 2°F change in outdoor temperature, the Digital Humidifier Control will automatically adjust the indoor RH by 1%.

The Digital Humidifier Control will accurately control the humidity in your home to a maximum of 45%.

The humidity values in Table 2 are targets based on outdoor temperature and the Digital HumidifierControl setting. The actual humidity may vary due to conditions in the home (cooking, showering, etc.).

TABLE2 – % Relative Humidity Guide

Outdoor Temperature (°F)

 

 

-10°F

0°F

10°F

20°F

30°F

40°F

 

 

 

 

 

 

 

 

 

 

 

1

10%

10%

10%

15%

20%

25%

RelativeHumidity

SettingDial

5

20%

25%

30%

35%

40%

45%

 

2

10%

10%

15%

20%

25%

30%

 

 

3

10%

15%

20%

25%

30%

35%

 

 

4

15%

20%

25%

30%

35%

40%

 

 

 

 

 

 

 

 

 

 

 

6

25%

30%

35%

40%

45%

45%

(%)

 

7

30%

35%

40%

45%

45%

45%

 

 

 

 

 

 

 

 

 

 

 

TABLE 3 – Operation Guide

Condition

Solution

Condensationon windows.

Reduce the setting on the control dial

 

by 1 increment.

 

 

Lack of humidity.

Increasethe settingon the controldial

 

by 1 increment.If the HumidifierControl

 

is alreadyat the maximumsettingof “7”,

 

set the Blower ActivationSwitch to

 

“ON”. The humidifiershould be plumbed

 

to hot water when using the Blower

 

Activationfeature.

 

 

Humidifierdoes not operate.

Turndial to “Test/Reset”.Make certain

 

HVAC blower is operating.If unit still

 

does not operate, consult a heating

 

contractor.

 

 

Humidifierwon’t shut off.

Turndial to “Off”. If unit continues to

 

operate, consult a heating contractor.

 

 

Testmode.

System operation is checked by setting

 

the knob to “Test/Reset”.Make certain

 

HVAC blower is operating. Humidifier

 

will operate for one minute. NOTE:

 

Placing the knob in “Test/Reset”resets

 

the Water Panel change timer.

 

 

Red “Call Dealer for Service”

Note the error code on the display (E1,

light flashes (Figure A).

E2, E3 or E4) and call your heating and

 

air conditioningdealer.

 

 

Model 60 only:

Refer to the Humidifier Owner’s

Yellow“Change Water

manual for instructions on changing

Panel” light flashes

the Water Panel or call your heating

(Figure A).

and air conditioning dealer for service.

 

After the Water Panel is replaced, turn

 

the Control knob to the “Test/Reset”

 

position until the green “Humidifier

 

On” light flashes, to reset the Water

 

Panel change timer.

 

 

8

9

Image 5
Contents Operating Instructions Automatic Digital Humidifier Control Digital Humidifier Control Indicator LightsBlower Activation Manual Mode Automatic Mode see Automatic Mode Manual Mode seeOutside Temperature Recommended RH OutdoorTemperature/ Indoor RelativeHumidityWater Panel Change Indicator Model 60 only TEST/RESETCondition Solution Outdoor Temperature F% Relative Humidity Guide 10F 20F 30F 40FCheck the Humidifier Operation Manual Humidifier ControlAnnual Summer Shutdown Digital Humidifier ControlResearch Products Corporation

4655, 62, 60 specifications

The Aprilaire 60, 62, and 4655 are cutting-edge solutions in the realm of indoor air quality. These models are designed to work with a range of heating and cooling systems, ensuring that every space can benefit from improved humidity control and air filtration.

One of the most notable features of the Aprilaire 60 and 62 models is their ability to manage humidity levels effectively. The Aprilaire 60 is a whole-home dehumidifier, designed to operate quietly and efficiently, helping to prevent mold, mildew, and other moisture-related issues. With a capacity to remove up to 70 pints of moisture per day, it’s particularly suited for larger homes or areas prone to dampness. The unit comes equipped with an automatic humidity control that allows for customizable settings, ensuring that your home remains at a comfortable humidity level year-round.

In contrast, the Aprilaire 62 model is designed specifically for homes in extremely damp climates that experience high humidity levels. This model delivers superior extraction capabilities, with an impressive removal rate of up to 90 pints per day. It features a built-in humidistat that enables homeowners to maintain their desired humidity levels automatically. Both models are straightforward to install and maintain, highlighting Aprilaire’s commitment to user-friendly products.

The Aprilaire 4655 is a different yet complementary model that focuses on air filtration. This air purifier is designed to capture airborne pollutants, such as dust, pollen, pet dander, and other allergens, ensuring cleaner indoor air. It employs a high-efficiency particulate air (HEPA) filter, which is effective in trapping particles as small as 0.3 microns, making it a vital addition for allergy sufferers.

All three models incorporate advanced technology that emphasizes energy efficiency. They are designed to operate quietly, ensuring that your comfort is never compromised. Furthermore, each unit is equipped with easy-to-use controls and indicators for filter replacement, which take the guesswork out of maintenance.

In summary, the Aprilaire 60, 62, and 4655 are exceptional products that address the necessity of humidity control and air filtration in residential environments. With their combination of technology, ease of use, and energy efficiency, these models represent effective solutions for those looking to enhance their indoor air quality.