Aprilaire 4655 Manual Humidifier Control, Check the Humidifier Operation, Annual Summer Shutdown

Page 6

Manual Humidifier Control

Figure C – Manual Humidifier Control

90-1237

Your Aprilaire humidifieris controlled by a Manual Humidifier Control (see Figure C). The Manual Humidifier Control is installed either in the cold air return duct or on an interior wall of the home. With the Manual HumidifierControl, it is important to anticipate a drop in outdoor temperature and reduce the setting accordingly to avoid excessive condensation, just as with the Digital HumidifierControl installed in Manual Mode (see page 5).

To determine the indoor RH, slowly turn the knob clockwise and counterclockwise and listen for 2 clicks. The indoor RH is within the range of the 2 clicks.

Check the Humidifier Operation

DIGITAL HUMIDIFIER CONTROL

Set the knob to “Test/Reset”, make sure that the water saddle valve is open and that there is electricity to the humidifier. The HVAC fan must be running for the humidifier to function. NOTE: Turning the knob to “Test/Reset” resets the “Change Water Panel” timer. The humidifier will only operate for 1 minute in test mode. (Model 400 and 400M: Floats must be down for the solenoid valve to allow water flow.) Reduce the Humidifier Control setting to the recommended inside humidity, depending on the outside temperature. DO NOT LEAVE IN TEST MODE

AS HUMIDIFIER WILL NOT OPERATE.

MANUAL HUMIDIFIER CONTROL

Set the knob to the highest setting, make sure that the water saddle valve is open and that there is electricity to the humidifier. The HVAC system must be operating for the humidifier to function. Confirm that the solenoid valve is energized and water is flowing into the humidifier. Return control knob to desired setting.

Annual Summer Shutdown

Digital Humidifier Control in Automatic Mode (see Figure A) and Blower Activation switch is in the ”OFF” position:

No adjustment is necessary.

Digital Humidifier Control in Automatic Mode (see Figure A) and Blower Activation switch is in the ”ON” position:

Set the knob to the “OFF” position.

Digital Humidifier Control in Manual Mode (see Figure B): Set the knob to the “OFF” position.

Manual Humidifier Control (see Figure C):

Set the knob to the “OFF” position.

10

11

Image 6
Contents Operating Instructions Digital Humidifier Control Indicator Lights Blower ActivationAutomatic Digital Humidifier Control Automatic Mode Manual Mode see Manual Mode Automatic Mode seeWater Panel Change Indicator Model 60 only OutdoorTemperature/ Indoor RelativeHumidityOutside Temperature Recommended RH TEST/RESET% Relative Humidity Guide Outdoor Temperature FCondition Solution 10F 20F 30F 40FAnnual Summer Shutdown Manual Humidifier ControlCheck the Humidifier Operation Digital Humidifier ControlResearch Products Corporation