Inspection and Service Instructions
1. Disconnect electrical power to the furnace and shut off water supply.
OUTLET | 2. | Disconnect the water line at the inlet |
| compression nut. | |
COMPRESSION |
| |
NUT | 3. | Remove the |
| ||
|
| the inlet side of the valve by using a |
ORIFICE |
| small nail or wire. |
| 4. Flush the | |
SOLENOID |
| replace with a new strainer, Service |
VALVE |
| Department, Part No. 4004. |
|
| |
| 5. Replace the | |
INLET |
| reconnect the inlet water line (Double |
|
| |
|
| Wrench To Prevent Leaking). |
| 6. | Disconnect the water line at the outlet |
INLET |
| compression nut. |
COMPRESSION | 7. | Remove the orifice from the copper |
NUT | ||
|
| or plastic tube and make sure this |
|
| small opening is unplugged. |
| 8. | Replace the orifice and reconnect the |
|
| outlet water line (Double Wrench To |
|
| Prevent Leaking). |
| 9. | Turn on water supply and reconnect |
|
| electrical power to the furnace. |
- 10 -