MAINTENANCE INSTRUCTIONS

for

APRILAIRE HUMIDIFIER MODEL 700

WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing.

 

 

5

 

3

2

 

4

 

1

6

1.

Front Cover

7

2.

Base

3.

Water Panel Evaporator

 

 

Assembly

 

4.

Distribution Tray

 

5.

”V” Notches

 

6.

Water Panel

 

7.

Scale Control Insert

 

8.

Drain Hose

 

9.

Power Cord

 

 

9

8

 

 

1.Note humidistat or control setting and turn dial to the “OFF” position.

2.Disconnect electrical power and turn off water supply.

3.Unlatch humidifier cover assembly (1) from base assembly (2) at the bottom of the cover, lift, and set aside.

4.Pull out the water panel evaporator assembly (3) by grasping at the top and tipping out.

5.Remove the black distribution tray (4) from the water panel evaporator assembly (3) by unsnapping the white plastic holding strips from the tabs at the end of the tray. Lightly scrape out any calcium deposits and clean the “V” notches (5) but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance.

6.Slide the Water Panel evaporator (6) out from the white plastic Scale Control Insert (7). Clean the Scale Control Insert by twisting and flexing it to loosen the calcium deposits or use a putty knife. Inspect the Water Panel evaporator (Stock No. 35) and replace with a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel evaporator back into the scale control insert with the red colored spot up and snap the black distribution tray (4) back into place.

7.Re-install the water panel evaporator assembly (3) into the base assembly (2). Push it in at the top between the retaining ribs that hold the assembly in place in a vertical posi- tion.

8.Remove the drain hose (8) from the bottom of the unit. Bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the drain fitting.

9.Reinstall cover assembly (1) by hooking at the top of the base assembly (2) and latching at the bottom.

10.Reconnect electrical power (9) and turn on the water supply.

11.Check system operation:

Humidifier Control: (Automatic or Manual) Check system operation by set- ting the knob to “Test.” With furnace blower operating and furnace calling for heat, humidifier will operate for one minute.

12. Set Humidifier or control to its original position.

MODEL 700

- 13 -

Image 14
Contents Automatic Humidifier Introduction Principle of Operation Page Automatic Mode Manual Mode-see pg Operation GuideFigure a Outdoor Temperature ºF Setting Dial % Relative Humidity GuideOutdoor-Indoor Relative Humidity Figure BIII. Effect of Water Characteristics IV. Annual Maintenance Inspection and Service Instructions Compression nutFor Aprilaire Humidifier ModelModel Model Limited Warranty Aprilaire Energy Recovery Ventilator Electronic Thermostats Aprilaire Zone Control SystemsService and Water Panel Replacement Record Service and Water Panel Replacement Record DP #10005406