The appliance does not always recognise all pipes and power cables.
The following conditions can contribute to inaccurate results:
–very thick walls
–weak battery
–deeply laid power cables or pipework
–shielded cables
–thick walls with thin pipes or power cables
–walls panelled with metal sheets
–very moist conditions
•This appliance is not suitable for detecting power cables in circuits,
–which are isolated from the mains power supply.
–through which direct current flows.
–which are used for computer or telecommunications systems.
•With this appliance pipework made of plastic or similar materials cannot be detected, only pipework made of metal.
•No warranty will be accepted for damage caused by manipulation
of the laser equipment, as well as of the ultrasound transmitter/receiver, and through disregard of the safety instructions.
Interaction with batteries:
•Leaking batteries can cause damage to the appliance. If you do not intend to use the appliance for an extended period, remove the batteries.
•Should the batteries leak, wear protective gloves and clean the battery compartment with a dry cloth.
•Keep batteries away from children. Children can put batteries into their mouths and swallow them. Should a battery ever be swallowed, seek medical attention IMMEDIATELY.
Technical data
Distance measurement by means of Ultrasound
Locating of: | power cables, metal, wood |
Laser class: | II (650 nm) |
Pmax: | < 1 mW |
Power supply: | 9 V block battery |
- 3 -