BRK electronic FCD2DDNP user manual Introduction, USER’S Manual

Page 1

USER’S MANUAL

120V PLUG-IN CARBON MONOXIDE ALARM WITH DIGITAL DISPLAY AND SILENCE FEATURE

Reliable Protection, Maximum

Convenience!

Just plug the alarm into a regular outlet, test, and it’s

ready to go!

• Memory stores highest levels of CO detected. Easy to display, easy to clear!

120V AC ~ 60 Hz 0.09A

M08-0054-001 P 04/03

Model FCD2DDNP

IMPORTANT!

PLEASE READ CAREFULLY AND SAVE.

This user’s manual contains important information about your Carbon Monoxide (CO) Alarm’s operation. If you are installing this CO alarm for use by others, you must leave this manual—or a copy of it—with the end user.

THIS USER’S MANUAL HAS BEEN RESIZED TO

PRINT OUT ON 8-1/2 x 11” PAGES.

BLACK page numbers reference the original printed document.

RED page numbers reference this web version.

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2

Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 How Your CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Understanding Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Using the Peak CO Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Where to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . . . . . .3/2 How to Install Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 If the Alarm Signal Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/3 Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/3 Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/3

What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . .4-5/3-4

What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/3 Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . . . . . . .4 Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . .4 How Can I Protect My Family? . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/4

Underwriters Laboratories Inc. UL2034 . . . . . . . . . . . . . . . . . . . . . . . . . .5/4

Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6/5

General Limitations Of CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6/5

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6/5

All Rights Reserved. © 2003 BRK Brands, Inc.

BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122 Consumer Affairs: (800) 323-9005 • www.firstalert.com

INTRODUCTION

BASIC SAFETY INFORMATION

Dangers, Warnings, and Cautions alert you to important operating instructions or to potentially hazardous situations. Pay special attention to these items.

THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide from ANY source of combustion. It is NOT designed to detect smoke, fire, or any other gas.

This CO Alarm is approved for use in single-family residences. It is NOT designed for marine or RV use.

This CO Alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.

The Silence Feature is for your convenience only and will not correct a CO problem. Always check your home for a potential problem after any alarm. Failure to do so can result in injury or death.

This CO Alarm should receive continuous 120VAC, 60 Hz, pure sine wave electrical power. Do not use in an extension cord or outlet con- trolled by a dimmer or switch.

NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to

“If Your CO Alarm Sounds” for more information. Failure to do so can result in injury or death.

Test the CO Alarm once a week. If the CO Alarm ever fails to test correctly, have it replaced immediately! If the CO Alarm is not work- ing properly, it cannot alert you to a problem.

This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure CO levels in compliance with Occupational Safety and Health Administration (OSHA) commer- cial or industrial standards. Individuals with medical conditions that may make them more sensitive to carbon monoxide may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30 ppm. For additional infor- mation on carbon monoxide and your medical condition contact your physician.

HOW YOUR CO ALARM WORKS

GENERAL INFORMATION

Leave your CO Alarm plugged in year-round. CO problems can occur any time during the year, and this Alarm can only alert you if it is plugged in and receiving power.

This CO Alarm is intended for use in a standard, unswitched 120V AC wall outlet. It is not intended for use in extension cords, power strips, or outlets controlled by a switch or dimmer. These may not provide continuous power to the unit. When fully powered, the unit samples the air and takes a new reading about every second. A microchip inside the unit stores each reading, and remembers the levels of CO it has been exposed to over time. The Alarm sounds when it has been exposed to a “critical” level of CO (measured in parts per million or “ppm”) within a specified time (measured in minutes). This CO Alarm features a permanently installed sensor, an indicator light, and an

85 dB alarm horn. It also has a Silence Feature to temporarily quiet the alarm horn.

MALFUNCTION WARNING

This unit performs self-diagnostic tests approximately every second. If the Alarm malfunctions, replace it immediately.

THE COVER OF YOUR CO ALARM

 

 

 

3

 

 

 

2

 

 

 

1

 

5

 

 

 

4

 

 

1

Test/Silence/Scroll Button: Press

3

Digital Display

 

and release to select mode (Test,

4

Air Vents

 

Memory, Clear Memory); Press

 

 

 

 

and hold to activate mode, or to

5

Alarm Horn: 85dB audible alarm

 

silence the alarm.

 

for test, alarm, and unit malfunc-

2

POWER/ALARM Light (Red)

 

tion warning.

 

 

1

Image 1
Contents USER’S Manual IntroductionUnderstanding Your CO Alarm InstallationWhere CO Alarms should not be Installed Using the Peak CO MemoryTesting and Maintenance If Your CO Alarm SoundsWhat YOU Need to Know about CO Underwriters Laboratories INC. UL2034 Limited Warranty General Limitations of CO AlarmsHow to Obtain Warranty Service

FCD2DDNP specifications

The BRK electronic FCD2DDNP is a state-of-the-art smoke and carbon monoxide alarm designed for residential and commercial safety. This device exemplifies the best in advanced detection technologies, ensuring users benefit from reliable protection against the dangers posed by smoke, fire, and harmful gases.

One of the key features of the FCD2DDNP is its dual-sensor technology. This innovative approach combines both photoelectric and ionization sensors, allowing the alarm to detect a wide range of fire types. Photoelectric sensors are particularly effective for detecting smoldering fires, which may produce a lot of smoke without much heat. On the other hand, ionization sensors are more responsive to fast-flaming fires, providing a comprehensive detection capability that enhances overall safety.

Another significant characteristic of the FCD2DDNP is its built-in carbon monoxide detector. Carbon monoxide is a silent killer, and this device actively monitors levels of this dangerous gas in the environment. The integrated CO sensor provides an additional layer of security, alerting users to dangerous conditions before they become life-threatening.

The FCD2DDNP also features a user-friendly design. Its intuitive controls allow for easy testing and maintenance, ensuring that the device is functioning correctly at all times. The alarm is equipped with a loud 85-decibel siren, which guarantees that alerts can be heard even during the night, crucial for waking individuals and ensuring their safety.

Moreover, the FCD2DDNP is designed with a long-lasting battery life. The device typically uses a sealed lithium battery that can last for up to 10 years, eliminating the need for frequent replacements. This feature not only enhances convenience but also ensures that the alarm remains operational without regular maintenance concerns.

In addition to its technical capabilities, the FCD2DDNP encompasses a sleek and unobtrusive design, making it easy to integrate into various home aesthetics. With its compact size, it can be installed in multiple locations, from hallways to living rooms, enhancing safety without compromising the visual appeal of the environment.

Lastly, the BRK electronic FCD2DDNP is compliant with rigorous safety standards, offering peace of mind for users. With its combination of advanced detection technologies, user-friendly features, and reliable performance, the FCD2DDNP stands out as a top choice for anyone looking to enhance their safety and protection against fire and carbon monoxide hazards.