BRK electronic Official User Manual for BRK 7010B and First Alert Smoke Alarms

Page 1

USER’S MANUAL

SMOKE ALARMS

AC Powered Photoelectric Smoke Alarm with Battery Back-Up and Silence Feature

Model 7010B

Input: 120V AC ~, 60Hz, 0.04A

AC Powered Photoelectric Smoke Alarm with Silence Feature

Model 7010

Input: 120V AC ~, 60Hz, 0.04A

IMPORTANT!

PLEASE READ CAREFULLY AND SAVE.

This user’s manual contains important information about your

Smoke Alarm’s operation. If you are installing this Smoke Alarm for use by others, you must leave this manual—or a copy of it—with the end user.

US Patent 6,377,182

 

 

Printed in Mexico

 

 

Models 7010,

M08-0050-000 Q 09/03

 

7010B

THIS USER’S MANUAL HAS BEEN RESIZED TO

PRINT OUT ON 8-1/2 x 11” PAGES.

TABLE OF CONTENTS

Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Before You Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3

Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Understanding the Indicator Lights

and Alarm Horn Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

If This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

If You Suspect a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Recommended Locations For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . .6

Locations To Avoid For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Limitations of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

All Rights Reserved. © 2003 BRK Brands, Inc.

BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122 Consumer Affairs: (800)323-9005 • www.firstalert.com • www.brkelectronics.com

All First Alert® and BRK® Smoke Alarms conform to regulatory requirements, including UL217 and are designed to detect particles of combustion. Smoke particles of varying number and size are produced in all fires.

Ionization technology is generally more sensitive than photoelectric technology at detecting small particles, which tend to be produced in greater amounts by flaming fires, which consume combustible

materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or a grease fire in the kitchen.

Photoelectric technology is generally more sensitive than ionization technology at detecting large particles, which tend to be produced in greater amounts by smoldering fires, which may smolder for hours

before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding.

For maximum protection, use both types of Smoke Alarms on each level and in every bedroom of your home.

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking materi- als properly. Never smoke in bed. 2) Keep matches or lighters away from chil- dren; 3) Store flammable materials in proper containers;

4)Keep electrical appliances in good condition and don’t overload electrical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys grease- and debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep portable heaters and open flames, like candles, away from flammable materi- als; 8) Don’t let rubbish accumulate.

Keep alarms clean, and test them weekly. Replace alarms immediately if they are not working properly. Smoke Alarms that do not work cannot alert you to a fire. Keep at least one working fire extinguisher on every floor, and an addition- al one in the kitchen. Have fire escape ladders or other reliable means of escape from an upper floor in case stairs are blocked.

BEFORE YOU INSTALL THIS SMOKE ALARM

IMPORTANT! Read “Recommended Locations for Smoke Alarms” and

“Locations to Avoid for Smoke Alarms” before beginning. This unit monitors the air, and when smoke reaches its sensing chamber, it alarms. It can give you more time to escape before fire spreads. This unit can ONLY give an early warning of developing fires if it is installed, maintained and located where smoke can reach it, and where all residents can hear it, as described in this manual. This unit will not sense gas, heat, or flame. It cannot prevent or extinguish fires.

Understand The Different Type of Smoke Alarms

Battery powered or electrical? Different Smoke Alarms provide different types of protection. See “About Smoke Alarms” for details.

Know Where To Install Your Smoke Alarms

Fire Safety Professionals recommend at least one Smoke Alarm on every level of your home, in every bedroom, and in every bedroom hallway or separate sleeping area. See “Recommended Locations For Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for details.

Know What Smoke Alarms Can and Can’t Do

A Smoke Alarm can help alert you to fire, giving you precious time to escape. It can only sound an alarm once smoke reaches the sensor. See “Limitations of Smoke Alarms” for details.

Check Your Local Building Codes

This Smoke Alarm is designed to be used in a typical single-family home. It alone will not meet requirements for boarding houses, apartment buildings, hotels or motels. See “Special Compliance Considerations” for details.

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Smoke Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury or death.

This unit will not alert hearing impaired residents. It is recommend- ed that you install special units which use devices like flashing strobe lights to alert hearing impaired residents.

Installation of this unit must conform to the electrical codes in your area; Article 760 of NFPA 70 (NEC), NFPA 72, NFPA 101; SBC (SBCCI); UBC (ICBO); NBC (BOCA); OTFDC (CABO), and any other local or building codes that may apply. Wiring and installation must be performed by a licensed electrician. Failure to follow these guidelines may result in injury or property damage.

This unit must be powered by a 24-hour, 120VAC pure sine wave 60Hz circuit. Be sure the circuit cannot be turned off by a switch, dimmer, or ground fault circuit interrupter. Failure to connect this unit to a 24-hour circuit may prevent it from providing constant protection.

This Smoke Alarm must have AC or battery power to operate. On Model 7010B Only:

If the AC power fails, battery back-up will allow the alarm to sound for at least 4 minutes. If AC power fails and the battery is weak, protection should last for at least 7 days. If AC power fails and the battery is dead or missing, the alarm cannot operate.

Never disconnect the power from an AC powered unit to stop an unwanted alarm. Doing so will disable the unit and remove your protection. In the case of a true unwanted alarm open a window or fan the smoke away from the unit. The alarm will reset automatical- ly when it returns to normal operation. Never remove the batteries from a battery operated unit to stop an unwanted alarm (caused by cooking smoke, etc.). Instead open a window or fan the smoke away from the unit. The alarm will reset automatically.

Connect this unit ONLY to other compatible units. See “How To Install This Smoke Alarm” for details. Do not connect it to any other type of alarm or auxiliary device. Connecting anything else to this unit may damage it or prevent it from operating properly.

On Model 7010B Only: This Smoke Alarm has a battery drawer which resists closing unless a battery is installed. This warns you the unit will not operate under DC power without a battery.

Do not stand too close to the unit when the alarm is sounding. It is loud to wake you in an emergency. Exposure to the horn at close range may harm your hearing.

Do not paint over the unit. Paint may clog the openings to the sensing chambers and prevent the unit from operating properly.

1

Image 1
Contents Fire Safety Tips Table of ContentsBefore YOU Install this Smoke Alarm USER’S ManualParts of this Smoke Alarm HOW to Install this Smoke AlarmFollow These Installation Steps STAND-ALONE Alarm onlyTo Lock the Battery Compartment Optional Locking FeaturesTo Unlock the Battery Compartment To Lock the Mounting BracketWeekly Testing Understanding the Indicator Lights and Alarm Horn PatternsRegular Maintenance If YOU Suspect a Problem If this Smoke Alarm SoundsResponding to AN Alarm Using the Silence FeatureLocations to Avoid for Smoke Alarms Recommended Locations For Smoke AlarmsAbout Smoke Alarms Limited Warranty Limitations of Smoke AlarmsSpecial Compliance Considerations

7010B, 7010 specifications

The BRK Electronic 7010B and 7010 are state-of-the-art smoke alarms designed to enhance safety and ensure peace of mind in residential and commercial buildings. These models blend innovative technology with user-friendly features, making them a preferred choice for many users.

One of the key characteristics of the BRK Electronic 7010B and 7010 is their advanced photoelectric sensing technology, which is particularly effective in detecting smoldering fires that produce a significant amount of smoke without an open flame. This type of sensor reduces false alarms, which can be triggered by steam or cooking smoke, thus allowing users to maintain peace in their homes without frequent disturbances.

The 7010B features a 10-year sealed battery, providing long-term reliability without the hassle of battery replacement. This built-in battery ensures that the unit remains functional over the typical lifespan of the alarm, providing continuous protection for a decade. Additionally, the battery seal prevents tampering, eliminating the risk of users removing the battery to silence unwanted alarms.

Equipped with a loud 85-decibel alarm, both models are designed to alert occupants promptly in the event of smoke detection. The alarm is powerful enough to wake sleeping individuals, which is crucial during nighttime emergencies. Complementing the audible alarm is a visual indicator, often featuring a bright LED that flashes to provide a clear visual alert of smoke detection.

Another notable feature of the BRK Electronic 7010B and 7010 is the integrated test/silence button. This button allows users to easily test the functionality of the alarm or silence the unit in the event of a non-threatening situation. This feature enhances user control and fosters a proactive approach to fire safety.

The units are also designed for easy installation, with a simple mounting bracket that allows for quick setup in any environment. Additionally, the 7010B and 7010 comply with various safety standards, reinforcing their reliability and effectiveness in smoke detection.

In summary, the BRK Electronic 7010B and 7010 smoke alarms stand out due to their advanced photoelectric technology, 10-year sealed battery, powerful alarm sound, and user-friendly features. These characteristics make them an excellent choice for anyone looking to enhance their fire safety measures while benefiting from a reliable and efficient smoke detection system.