BRK electronic 7010B Understanding the Indicator Lights and Alarm Horn Patterns, Weekly Testing

Page 4

UNDERSTANDING THE INDICATOR LIGHTS AND ALARM HORN PATTERNS

 

AC Power

DC Power

 

All Models

Model 7010B

 

 

 

Normal Operation

Constant Green LED

Green LED Off

 

Flashing Red LED

Flashing Red LED

 

approx. once/minute

approx. once/minute

 

No Audible Alarm

No Audible Alarm

 

 

 

 

 

 

 

 

 

Test Condition

Constant Green LED

Green LED Off

 

Rapidly Flashing

Rapidly Flashing

 

Red LED

Red LED

 

Audible Alarm

Audible Alarm

 

 

 

 

 

 

Alarm Condition*

Constant Green LED

Green LED Off

(Initiating Unit)

Rapidly Flashing

Rapidly Flashing

 

 

Red LED

Red LED

 

Audible Alarm

Audible Alarm

 

 

 

 

 

 

Silence Mode

Red LED flashes once

Red LED flashes once

 

every 10 seconds

every 10 seconds

 

 

 

 

 

 

Low Battery

Not Applicable

Alarm “chirp’’ approx.

 

 

once/minute

 

 

 

NOTE: When power is applied, unit(s) may alarm momentarily.

*When any Smoke Alarm in an interconnected series triggers an alarm,

its red LED will flash rapidly. The red LEDs will remain OFF on any remaining alarms in the series. This feature helps responders identify which unit(s) triggered the alarm.

WEEKLY TESTING

NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to your home. The built- in test switch accurately tests the unit’s operation as required by Underwriters Laboratories, Inc. (UL). If you choose to use an aerosol smoke product to test the Smoke Alarm, be certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety Standards, and use it only as directed. Use of non-UL Listed products or improp- er use of UL Listed products may affect the Smoke Alarm’s sensitivity, and may void your warranty.

If the Alarm ever fails to test properly, replace it immediately. Products under warranty may be returned to the manufacturer for replacement. See “Limited Warranty” at the end of this manual.

DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.

It is important to test this unit every week to make sure it is working prop- erly. Using the test button is the recommended way to test this Smoke Alarm. Press and hold the test button on the cover of the unit until the alarm sounds (the unit may continue to alarm for a few seconds after you release the button). If it does not alarm, make sure the unit is receiving power and test it again. If it still does not alarm, replace it immediately. During testing, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.

When testing a series of interconnected units you must test each unit individ- ually. Make sure all units alarm when each one is tested.

REGULAR MAINTENANCE

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge.

This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working properly:

Test it at least once a week.

Clean the Smoke Alarm at least once a month; gently vacuum the outside of the Smoke Alarm using your household vacuum’s soft brush attachment. Test the Smoke Alarm. Never use water, cleaners or solvents since they may damage the unit.

If the Smoke Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately.

Relocate the unit if it sounds frequent unwanted alarms. See “Locations To Avoid For Smoke Alarms” for details.

Model 7010B Only: When the battery back-up becomes weak, the Smoke Alarm will “chirp” about once a minute (the low battery warning). This warning should last 7 days, but you should replace the battery immediately to continue your protection.

Model 7010B Only – Choosing a replacement battery:

Your Smoke Alarm requires one standard 9V battery. The following batteries are acceptable as replacements: Duracell #MN1604, (Ultra) #MX1604; Eveready (Energizer) #522. You may also use a Lithium battery like the Ultralife U9VL-J for longer service life between battery changes. These batteries are available at many local retail stores.

Actual battery service life depends on the smoke alarm and the environment in which it is installed. All the batteries specified above are acceptable replacement batteries for this unit. Regardless of the manufacturer’s suggest- ed battery life, you MUST replace the battery immediately once the unit starts “chirping” (the “low battery warning”).

4

Image 4
Contents Table of Contents Fire Safety TipsBefore YOU Install this Smoke Alarm USER’S ManualHOW to Install this Smoke Alarm Parts of this Smoke AlarmFollow These Installation Steps STAND-ALONE Alarm onlyOptional Locking Features To Lock the Battery CompartmentTo Unlock the Battery Compartment To Lock the Mounting BracketWeekly Testing Understanding the Indicator Lights and Alarm Horn PatternsRegular Maintenance If this Smoke Alarm Sounds If YOU Suspect a ProblemResponding to AN Alarm Using the Silence FeatureLocations to Avoid for Smoke Alarms Recommended Locations For Smoke AlarmsAbout Smoke Alarms Limited Warranty Limitations of Smoke AlarmsSpecial Compliance Considerations

7010B, 7010 specifications

The BRK Electronic 7010B and 7010 are state-of-the-art smoke alarms designed to enhance safety and ensure peace of mind in residential and commercial buildings. These models blend innovative technology with user-friendly features, making them a preferred choice for many users.

One of the key characteristics of the BRK Electronic 7010B and 7010 is their advanced photoelectric sensing technology, which is particularly effective in detecting smoldering fires that produce a significant amount of smoke without an open flame. This type of sensor reduces false alarms, which can be triggered by steam or cooking smoke, thus allowing users to maintain peace in their homes without frequent disturbances.

The 7010B features a 10-year sealed battery, providing long-term reliability without the hassle of battery replacement. This built-in battery ensures that the unit remains functional over the typical lifespan of the alarm, providing continuous protection for a decade. Additionally, the battery seal prevents tampering, eliminating the risk of users removing the battery to silence unwanted alarms.

Equipped with a loud 85-decibel alarm, both models are designed to alert occupants promptly in the event of smoke detection. The alarm is powerful enough to wake sleeping individuals, which is crucial during nighttime emergencies. Complementing the audible alarm is a visual indicator, often featuring a bright LED that flashes to provide a clear visual alert of smoke detection.

Another notable feature of the BRK Electronic 7010B and 7010 is the integrated test/silence button. This button allows users to easily test the functionality of the alarm or silence the unit in the event of a non-threatening situation. This feature enhances user control and fosters a proactive approach to fire safety.

The units are also designed for easy installation, with a simple mounting bracket that allows for quick setup in any environment. Additionally, the 7010B and 7010 comply with various safety standards, reinforcing their reliability and effectiveness in smoke detection.

In summary, the BRK Electronic 7010B and 7010 smoke alarms stand out due to their advanced photoelectric technology, 10-year sealed battery, powerful alarm sound, and user-friendly features. These characteristics make them an excellent choice for anyone looking to enhance their fire safety measures while benefiting from a reliable and efficient smoke detection system.