Ei Electronics Ei 3100RF manual Battery Missing indicator

Page 8

1.Pull cover open at tab. Remove cover from base by sepa- rating at rear snap-in hinges by rotating cover backwards.

2.Place the base on ceiling or wall exactly where you want to mount the unit. With a pencil, mark the location of the screw holes.

3.Taking care to avoid any electrical wiring in the ceiling or wall, drill a hole through the centres of the marked locations. Push the plastic Screw Anchors provided into the drilled holes. Screw in firmly.

(b) Connecting the battery

The battery is easily removed from the holder by holding back one of the plastic clips while lifting the battery with the other hand.

Snap Battery Connectors to Battery. They fit together only one way.

Gently push Battery into Battery Holder

With a pencil, write the date of battery installation on the inside of the cover to remind you when to replace the battery. To close the cover match up snap-in hinges and gently press together until base and cover snap together. Test the installed Smoke Alarm - see section “Manually Testing your Smoke Alarm”.

NOTE: You may hear a loud chirp when attaching the Battery Connectors to the Battery.

Battery Missing indicator

The unit is fitted with a warning flag which pops up when the battery is removed. This prevents the cover from closing when there is no battery in the unit. When the battery is being installed or changed, this flag must be held down while gently pushing the Battery into the Battery Holder. (Figure 8).

Figure 8

7.Check the radio link interconnection by holding the test but- ton down until the amber light has come on continuously – this indicates that the alarm is now transmitting radio link signals. You should now be able to hear the other alarm(s) in the dis- tance. If you do not hear the other alarm(s) then you may need to rotate/resite the alarm (see section 5.2 below).

8

Image 8
Contents Smoke Alarm Instruction LeafletTable of Contents Read this FirstSingle Storey Dwelling Locating Your Smoke AlarmsIntroduction Recommended locations, Figures 2, 3 Single storey dwellingPositioning Your Smoke Alarm Checking you can hear your Smoke AlarmsMulti Storey Dwellings Recommended ProtectionLocations to Avoid Wall MountingOn a sloping Ceiling Installing Your Smoke Alarms Attaching to Ceiling or WallBattery Missing indicator House Coding Your Alarms If Radio Link is not workingTesting and Maintaining Your Smoke Alarms House Code ProcedureChecking the Wireless Interconnect Test/Hush Button to Control Nuisance Alarms Ei3105RF onlyDust & Insect Contamination Cleaning your Smoke AlarmAutomatic Self-Test Ei3105RF only Troubleshooting Your Alarms Replacing the BatteryAlarms sounds for no apparent reason Alarm fails to sound when the test button is pressedImportant Safeguards Alarms sound but the wireless interconnection does not workFire Safety Hints Smoke Alarm & RF Limitations Limitations of Smoke AlarmsGetting Your Smoke Alarm Serviced Limitations of Radio Frequency SignalsFive Year Guarantee Limited Technical Specification RF Power +5dBmDuration of House Code Mode 15 minutes Test ButtonEi3100RFEi Electronics Page Page

Ei 3100RF specifications

The Ei Electronics Ei 3100RF is an advanced smoke alarm designed to enhance safety and peace of mind in residential settings. This model stands out due to its integration of cutting-edge technologies and user-friendly features that cater to modern needs.

One of the key features of the Ei 3100RF is its unique radio frequency (RF) interlinking capability. This allows multiple alarms to communicate with each other wirelessly, ensuring that if one alarm detects smoke, all interconnected alarms will sound an alert. This interlinking technology is invaluable in larger homes where the sound from a single alarm may not reach all areas effectively, thereby enhancing overall safety.

The Ei 3100RF utilizes an advanced optical smoke sensing technology. This means it can detect smoldering fires that may not immediately produce flames but can generate significant amounts of smoke. This capability is particularly crucial in residential environments, where early detection can save lives and property. The alarm boasts a high-performance sensing chamber that minimizes false alarms, a common concern with traditional smoke detectors.

Another notable characteristic of the Ei 3100RF is its built-in 10-year lithium battery. This eliminates the hassle of changing batteries regularly and ensures that the unit remains operational for an extended period. The battery's longevity is a significant advantage, as it provides uninterrupted monitoring and alarm functionality over the years.

Ease of installation is yet another feature of the Ei 3100RF. The unit includes a simple mounting process that can be completed in a matter of minutes, making it accessible even for individuals without extensive DIY experience.

Furthermore, the Ei 3100RF incorporates a test button, allowing users to easily verify that the alarm is functioning correctly. Regular testing is essential for maintaining safety standards, and this feature encourages proactive behavior among homeowners.

In addition to its practical features, the Ei 3100RF is designed with a sleek, modern aesthetic, making it suitable for a variety of interior styles without being an eyesore. Safety doesn't have to compromise design, and this product exemplifies that philosophy.

In conclusion, the Ei Electronics Ei 3100RF is an excellent choice for those seeking a reliable, advanced smoke alarm. With its RF interlinking technology, optical detection capabilities, long-life battery, easy installation, and user-friendly features, the Ei 3100RF addresses both functional and aesthetic needs in smoke detection.