Hearth and Home Technologies SFE-MKLB3530PP manual Electrical Wiring, Service Instructions

Page 7

4 Electrical Wiring

X1

 

Lamp

Interlock on

 

 

 

 

 

Projector

Media Cabinet only

 

 

S7

Remote Receiver

 

 

M

 

 

 

Motor

 

 

 

 

 

 

 

P1

 

Flame

 

 

 

 

Power Supply Module

 

Heat

 

 

 

 

 

 

RD

Hot Line

Ground

Neutral

Branch Circuit

 

 

 

 

 

 

 

Flame

 

 

 

 

Terminal Strip

 

4050-309

 

 

 

 

ON

Wall Switch

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat

NEMA-5IEC 320 C13/C14 12 VOC

 

 

 

 

WH

 

 

Power

J1

 

 

RD

WH

 

 

5

 

 

 

Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ember Bed & Back Log

 

 

4050-310

 

 

 

 

 

 

 

 

 

 

 

R2

 

 

Wall Thermostat

 

 

 

 

LED LED LED

 

 

 

 

 

 

D1

R1

 

 

 

 

 

 

 

 

 

 

Heater

Hi Limit

 

 

LED LED LED

 

 

 

 

 

 

Heat Indicator

 

 

 

Heater-Blower

 

 

 

 

 

 

M

Motor

5 Service Instructions

WARNING! Disconnect power at circuit breaker before at- tempting any maintenance or cleaning to reduce the risk of fire, electrical shock or personal injury.

A. Replacing the Light Bulb

This appliance uses a single 12 Volt, 35 Watt, MR-16 bulb. The bulb is located behind the smoke shield.

A spare is provided with the unit. Replacement bulbs (Part No. 4050-123) are available through your Simplifyre dealer.

Turn off power to the unit at the main service panel.

Let the fireplace cool if it has been operating.

Release the spring pins and remove the upper shield.

Remove the two screws on the projector basket.

Rotate the housing down to access the bulb.

Remove the screws holding the bulb and socket.

Unplug the bulb from the socket.

Replace the bulb.

Re-assemble in the reverse order.

B. Screen Cleaning

During shipment, installation, handling, etc., the screen surface may collect dust particles; these can be removed by lightly wiping with a clean, dry cloth.

C. Maintenance of Motors

The motors used on the fan and flame projector assembly are pre-lubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended.

D. Resetting the Temperature Cutout Switch

The heater on this fireplace is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cutout will turn OFF the heater/blower. The switch is reset by turning the unit OFF, waiting 10-15 minutes and switching the unit back ON.

7

Hearth & Home Technologies Inc. • Plug & Play • 4050-317 Rev A • 04/08

Image 7
Contents Homeowner’s Installation & Operating Manual INSTALLER/CONSUMER Safety InformationTable of Contents Do not 1Important InstructionsFraming Wall Switch and Thermostat ConnectionsUnpacking the Unit Locating Your Electric FireplaceFraming Dimensions Fireplace DimensionsRemote Control Initialization Remote ControlControl Usage Service Instructions Electrical WiringTo control the fireplace with a single switch How to Obtain Service Warranty