4 Electrical Wiring
X1
| Lamp | Interlock on |
|
| ||
|
|
| ||||
Projector | Media Cabinet only |
|
| |||
S7 | Remote Receiver | |||||
|
| M |
|
| ||
| Motor |
|
|
| ||
|
|
|
| P1 |
| Flame |
|
|
|
| Power Supply Module |
| Heat |
|
|
|
|
|
|
RD
Hot Line
Ground
Neutral
Branch Circuit
|
|
|
|
|
|
| Flame |
|
|
|
| Terminal Strip |
| ||
|
|
|
| ON | Wall Switch | ||
|
|
|
| 1 |
| ||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Heat |
|
|
|
| WH |
| ||
| Power | J1 |
|
| RD | WH | |
|
| 5 |
|
| |||
| Supply |
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
| Ember Bed & Back Log |
|
| |
|
|
|
|
|
|
| |
|
|
|
| R2 |
|
| Wall Thermostat |
|
|
|
| LED LED LED |
|
|
|
|
|
| D1 | R1 |
|
|
|
|
|
|
|
|
|
| |
Heater | Hi Limit |
|
| LED LED LED |
|
|
|
|
|
| Heat Indicator |
|
|
| |
|
|
|
|
|
|
M
Motor
5 Service Instructions
WARNING! Disconnect power at circuit breaker before at- tempting any maintenance or cleaning to reduce the risk of fire, electrical shock or personal injury.
A. Replacing the Light Bulb
This appliance uses a single 12 Volt, 35 Watt,
A spare is provided with the unit. Replacement bulbs (Part No.
•Turn off power to the unit at the main service panel.
•Let the fireplace cool if it has been operating.
•Release the spring pins and remove the upper shield.
•Remove the two screws on the projector basket.
•Rotate the housing down to access the bulb.
•Remove the screws holding the bulb and socket.
•Unplug the bulb from the socket.
•Replace the bulb.
•
B. Screen Cleaning
During shipment, installation, handling, etc., the screen surface may collect dust particles; these can be removed by lightly wiping with a clean, dry cloth.
C. Maintenance of Motors
The motors used on the fan and flame projector assembly are
D. Resetting the Temperature Cutout Switch
The heater on this fireplace is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cutout will turn OFF the heater/blower. The switch is reset by turning the unit OFF, waiting
7 | Hearth & Home Technologies Inc. • Plug & Play • |