Hearth and Home Technologies GBST4336I, GBFL4136I Gas Information, Fuel Conversion, Gas Pressure

Page 27

11 Gas Information

A. Fuel Conversion

Make sure the appliance is compatible with available gas types.

Conversions must be made by a qualified service technician (NFI certified or factory-trained) using Hearth & Home Technologies specified and approved parts.

B. Gas Pressure

Optimum appliance performance requires proper input pressures.

Gas line sizing requirements will be determined in ANSI Z221.3 National Fuel Gas Code in the USA and CAN/ CGA B149 in Canada.

Pressure requirements are:

Gas Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 in. w.c.

11.0 in. w.c.

Maximum inlet pressure

14.0 in. w.c.

14.0 in. w.c.

Manifold pressure

3.5 in. w.c.

10.0 in. w.c.

C. Gas Connection

Refer to Reference Section 16 for location of gas line access in appliance.

Gas line may be run through knockout(s) provided.

The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes.

Pipe incoming gas line into valve compartment.

Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve.

WARNING! Risk of Fire or Explosion! Support control when attaching pipe to prevent bending gas line.

• A small amount of air will be in the gas supply lines.

WARNING! Risk of Fire or Explosion! Gas build-up dur- ing line purge could ignite.

WARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure may cause explosion.

Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

Note: Have the gas supply line installed in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2in. (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Purge should be performed by technician certified by NFI or factory-trained.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

WARNING! Risk of Fire, Explosion or Asphyxiation! Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loos- ened during shipping and handling.

WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce burner orifice 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce burner orifice 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Heatilator • GBST4336I, GBFL4136I • 2135-900 Rev. B • 3/08

27

Image 27
Contents What to do if you smell gas ModelHomeowner Reference Information CongratulationsUser Guide Table of ContentsAppliance Setup TroubleshootingReference Materials Limited Lifetime Warranty Gas Appliance Fireplace Limited Lifetime WarrantyListing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Decorative Doors and Fronts Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseGBFL4136I GBFL4136I Mantel Projection Mantel and Wall Projections GBST4336I Mantel ProjectionNon-Combustible Zone Combustible Mantel Legs or Wall ProjectionsVent Termination Minimum Clearances Termination LocationsModels Pipe Size Vent Information and DiagramsVent Guidelines Vent System ConfigurationVertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingInstalling Outside Air Kit Damper Assem- bly Appliance PreparationGas and Electrical Connections Proper Positioning, Leveling And Securing Securing and Leveling the ApplianceAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsHeatilator GBST4336I, GBFL4136I 2135-900 Rev. B Electrical Service and RepairJunction Box Detail Junction Box InstallationGBFL4136I Pier Mantel Projection FinishingFacing Material Noncombustible Facing DiagramSplatter Guard To install the Splatter GuardTo Remove the Splatter Guard To Close the Lower Access PanelAppliance Setup Models GDST4336I, GDFL4136I, GDCL4136I, GBST4336I, GBFL4136I Install the Log AssemblyÎModel GDCR4136I Placement of Log #2Burner Install Trim Kits and Surrounds Air Shutter SettingAir Shutter Settings Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Intellifire Ignition System Reference Materials Appliance Dimension DiagramFront View Log Set Assembly Service PartsPart number list on following At Depot GBST4336IGBFL4136I Stocked Service Parts ListGBST4336I , GBFL4136I IPI Valve AssemblyContact Information
Related manuals
Manual 50 pages 62.47 Kb

GBST4336I, GBFL4136I specifications

Hearth and Home Technologies has made significant strides in the realm of contemporary heating solutions with their innovative products, the GBST4336I and GBFL4136I fireplace inserts. These models exemplify a blend of cutting-edge technology, aesthetic design, and user-friendly features aimed at enhancing the home heating experience.

The GBST4336I, known for its striking design and powerful performance, offers a modern solution to traditional heating methods. This model showcases a large viewing area, providing an expansive glimpse into the mesmerizing flames. Its efficient combustion system allows for exceptional heat output while minimizing emissions, making it an eco-friendly choice for homeowners. The insert is designed to fit seamlessly into most existing fireplace spaces, significantly enhancing the ambiance and warmth of any living area.

On the other hand, the GBFL4136I model is tailored for those seeking a more traditional wood-burning experience combined with modern efficiency. This insert features an impressive firebox capacity, allowing users to load more wood for longer burn times. The innovative air wash system keeps the glass clean, ensuring an unobstructed view of the fire. Additionally, the optional blower enhances heat circulation throughout the room, making it perfect for large spaces.

Both models are equipped with advanced technologies that contribute to their reliability and performance. The adjustable burn settings allow users to regulate heat output based on their specific needs, making these inserts versatile for different settings. Furthermore, they include the latest in safety features such as automatic shut-off capabilities, ensuring peace of mind while enjoying the warmth of the fire.

Aesthetically, both the GBST4336I and GBFL4136I come with customizable options, allowing homeowners to choose from various trim and finish choices to fit their home décor. The modern design elements, combined with classic fireplace features, ensure that these inserts not only heat the space but also serve as a stunning focal point in any room.

In summary, Hearth and Home Technologies' GBST4336I and GBFL4136I fireplace inserts stand out for their exceptional design, advanced technology, and practicality. They cater to the needs of modern homeowners by offering efficient heating solutions while maintaining an inviting and stylish atmosphere. With features that prioritize performance and safety, these inserts are an excellent choice for anyone looking to enhance their living space with the warmth and beauty of a fire.