Interconnect & Remote Control Feature

Models Ei261ENRC & Ei261DENRC

The Problem

Audibility throughout the home is a priority, as a situation could arise where a CO alarm is installed in a downstairs kitchen, which has a fossil fuel burning appliance within it, and the alarm signal may not be heard in the upstairs bedrooms or indeed other rooms.

The Solution!

Use the interconnect feature on the Ei261ENRC/Ei261DENRC to connect to your existing Ei160RC smoke/heat alarm installation. Then, you must introduce an Ei1529RC Alarm Control Switch

to provide control over the whole system.

The interconnect feature allows the CO alarm to trigger all Ei160RC mains smoke/heat alarms installed and vice-versa - giving increased audibility in either a CO or fire situation. If all alarms are sounding, pressing ‘Locate’ on the Ei1529RC Alarm Control Switch will silence all the alarms except the alarm sensing a CO or fire situation. This gives control over the system and allows occupants to select the safest action and/or escape route.

Additionally, if found to be a false alarm, simply press ‘Hush’ on the Control Switch to silence the alarm. The entire alarm system can also be tested regularly by pressing the ‘Test’ switch.

Audibility of

Audibility when

CO Alarm Only

CO & Smoke Alarms are

 

 

 

interconnected

Bedroom Landing Bedroom

Bedroom Landing Bedroom

Living

 

 

Living

 

 

Room

Hallway

Kitchen

Room

Hallway

Kitchen

 

Smoke Alarm

 

Smoke Alarm

 

CO Alarm

 

 

CO Alarm

 

 

 

 

 

Alarm Control Switch

Wiring Diagram -

Ei1529RC Alarm Control Switch

Ei160RCEi160RCEi160RC

Smoke/Heat Alarm Smoke/Heat Alarm Smoke/Heat Alarm

Ei1529RC Alarm Control Switch

Wall mounted

Supplied with surface box, can be flush mounted using a standard 35mm deep electrical socket box.

Can be fitted anywhere in the system

For use when interconnecting Ei160RC smoke/heat alarms with Ei260 Series CO alarms

Allows Alarm Test, Hush, Locate and Mains Check functions

230C

AC

Main

Supply

Ei260 Series

Ei1529RC Control

CO Alarms

Switch

Ancillary Options For Ei260 Series

Ei128RBU Relay

Internal 5 Amp relay with Volt-free ' clean' contacts

Contacts rated to 240V AC

Mains operated

10yr+ rechargeable cell back-up

For use with Ei128COV cover to enable remote siting

Switchable pulse or continuous output options

Battery back-up allows contacts to switch even if mains power supply fails

For use with Ei260 Series alarms only

SAB300 Strobe

Xenon beacon

Mains operated

3W Xenon tube, 0.9Hz flash rate

For connection through an Ei128RBU relay

Available with clear ('C') or red ('R') lens (add suffix to product code)

Integral mounting base

GSV415SA Gas

Solenoid Valve

Mains operated

For connection through an Ei128RBU relay

Closes internal valve when mains is applied

Push button reset

1/2 “ internal parallel pipe thread to ISO7-1

Ei261MEN & Ei261M Replacement Sensor Module

Simple plug-in installation

Doubles life cycle of the product

'Ei261MEN' to suit models Ei261ENRC/Ei261DENRC/Ei261DEN/Ei261EN

'Ei261M' to suit models Ei261D/Ei261

9

Image 9
Contents Product Guide for Carbon Monoxide Alarms Why you should fit Ca Effective Solutions fromWhat is CO & why does it need to be monitored? What are the main sources of CO?Europes Leading Manufacturer Rbon Monoxide CO AlarmsWhat are the effects of CO poisoning? Is there any evidence of CO in the home?Calibration Answer to Reliable Detection Nominal Time to Alarm & % COHbLocating and Positioning CO Alarms How do Ei CO Alarms Work?Where should CO Alarms be located? Where should CO Alarms be positioned?Innovative Design & Practical Features Memory Feature Product SpecificationsQuick Test Feature Reliable, Proven SounderReplaceable sensor doubles the life of the alarm Why Rechargeable Vanadium Pentoxide Lithium Cells?Series The Specifier’s First Choice Ei261ENRCWiring Diagram Ei1529RC Alarm Control Switch Interconnect & Remote Control FeatureAncillary Options For Ei260 Series Models Ei261ENRC & Ei261DENRCSeries DIY Battery Only Ei205ENA Series Mains Powered Alarm Ei225ENContractors First Choice Series DIY Mains OnlyProduct Information Technical Guides Customer Service Helpline 0870 758