Hearth and Home Technologies FL92 owner manual Chimney Components, Catalog #

Page 44

C. Chimney Components

The following pictures show only those chimney components which may be safely used with this fireplace.

Catalog #

Description

CAK5A

Chimney Air Kit

ID4

Insulated Duct/Outside Air

 

 

UD4

Uninsulated Duct/Outside Air

SL1106

Chimney Section - 6 in. (152 mm) long

 

 

SL1112

Chimney Section - 12 in. (305 mm) long

SL1118

Chimney Section - 18 in. (457 mm) long

SL1136

Chimney Section - 36 in. (914 mm) long

 

 

SL1148

Chimney Section - 48 in. (1219 mm) long

SL11

Chimney Stabilizer

 

 

SL1130

Chimney Offset/Return - 30 deg

FS538

Ceiling Firestop - Straight

 

 

FS540

Ceiling Firestop - 30 deg

AS10

SL1100 Straight Attic Insulation Shield, 24 in. (610 mm)

 

 

JB577

Chimney Joint Band

 

 

CB576

Chimney Bracket

RF570

Roof Flashing - Flat to 6/12 Pitch

 

 

RF571

Roof Flashing - 6/12 to 12/12 Pitch

TR11

Round Termination Cap

 

 

TR11T

Round Telescoping Termination Cap

TCT1175

Terra Cotta Termination Cap

 

 

ST1175

Square Termination Cap

 

 

CT56

Chase Top

LDS33

Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)

 

 

LDS46

Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m)

LDS-BV

Decorative Shroud - 26 in. x 26 in. (660 mm x 660 mm)

 

 

 

Field Constructed Shrouds (See “Woodburning

 

Termination Cap”)

CT-11A

Adapter-May be used with the following Copper Caps

 

CT-King

 

 

 

CT-Queen

 

 

 

CT-Bishop I

 

 

 

CT-Bishop II

 

 

 

CT-Knight I

 

 

 

CT-Pawn

 

 

ID4 Insulated Duct

4 in. (102 mm) i

42 in.

(1067 mm)

UD4 Uninsulated Duct

4 in. (102 mm) i

42 in. (1067 )

A

13 in.

11 in.(330 mm)

(279 mm)

B

Chimney Sections

 

A

 

 

B

Catalog #

in

 

mm

in

 

mm

SL1106

6

 

152

4-3/4

 

121

SL1112

12

 

305

10-3/4

 

273

SL1118

18

 

457

16-3/4

 

425

SL1136

36

 

914

34-3/4

 

883

 

 

 

 

 

 

 

SL1148

48

 

1219

46-3/4

 

1187

A = Actual Length

B = Effective Length (length of

chimney part after it has

been snapped to another)

14 in.

14 in.

 

 

(356 mm)

 

 

(356 mm)

 

 

Inside

 

 

20-3/4 in.

Diameter

5-1/4 in.

 

(527 mm)

11 in.

(133 mm)

4 in. (102 mm)

 

(279 mm)

 

13 in.

 

Outside Diameter

(330 mm)

 

 

13 in.

 

 

 

 

 

 

(330 mm)

 

CAK5A Chimney Air Kit

SL11

Vent Stabilizer

 

 

 

44

Heatilator • Multi-Sided Woodburning Fireplace • 34955 • Rev V • 11/08

Image 44
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsNumber Model Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Limited Warranty Hearth & Home Technologies Limited Warranty 4021-645A Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Seasoned Wood Starting a FireGrate FirescreenGlass Doors Vented Gas Log Sets & Gas Log LightersOptional Components Clear SpaceWood Fuel Maintainance and Service Chimney Inspection/CleaningDisposal of Ashes Creosote Formation and Need for RemovalGlass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Select Fireplace LocationClearances Air Space ClearancesSidewalls/Surrounds Frame the FireplaceInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Install Outside Air Kit AK14/AK18 InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield 330 mmComplete Installation Install FlashingFollowing steps should be skipped if using a chase Cut out Hole in RoofChimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175 Square Termination CapTCT1175 Terra Cotta Cap Shrouds Radiation ShieldField Constructed Shrouds Open Top Shroud TR11/TR11T caps require radiation shieldMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield required= 1/k x inches of thickness FinishingHearth Extension Hearth Extension Dimensions Finishing Material In. Micore or equivilent insulationCombustible Mantel Flush FrontAccessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.113 mm Fireplace DimensionsReference Materials Chimney Components Catalog #15-1/4 387 mm 15-3/4 400 mm Service Parts FL92Contact Information

FL92 specifications

Hearth and Home Technologies (HHT) has long been recognized as a leader in the hearth industry, providing innovative and efficient heating solutions. Among its impressive lineup, the FL92 stands out as a versatile and modern gas fireplace that enhances both ambiance and functionality in various living spaces.

One of the main features of the FL92 is its expansive viewing area. The large glass front offers an unobstructed view of the flames, creating a mesmerizing focal point for any room. It allows consumers to enjoy the warmth and beauty of a traditional fire without the hassle of wood or ash cleanup. The design effectively blends contemporary aesthetics with practicality, making it an appealing choice for modern homes.

In terms of technology, the FL92 is equipped with advanced heating capabilities. It utilizes a powerful yet efficient burner system that provides reliable heat output while maximizing fuel efficiency. This means homeowners can enjoy a cozy atmosphere on chilly evenings while being mindful of energy consumption, potentially leading to lower utility bills.

Additionally, the FL92 features a variety of customizable options to suit individual preferences and home décor. Customers can choose from different finishes, media options, and decorative fronts to create a personalized look that complements their interior design. This level of customization ensures that the FL92 can be seamlessly integrated into any space, whether it’s a contemporary loft or a traditional living room.

Another standout characteristic of the FL92 is its easy installation and user-friendly operation. HHT has designed the unit with the homeowner in mind, making it compatible with a variety of installation scenarios, including zero-clearance applications. This versatility simplifies the process for contractors and homeowners alike.

Safety is also a top priority for HHT, and the FL92 is designed with several safety features, including an automatic shut-off function and a tempered glass front that remains cool to the touch. These elements not only provide peace of mind but also contribute to the overall user-friendly experience.

In conclusion, the Hearth and Home Technologies FL92 is a modern gas fireplace that combines aesthetic appeal with advanced heating technology and safety features. Its spacious viewing area, customizable options, and efficient operation make it an excellent choice for those looking to enhance their living spaces with the warmth and ambiance of a sophisticated fireplace. Whether for new builds or renovation projects, the FL92 stands out as a reliable and stylish option in the world of home heating solutions.