LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS
1."STOP!" Read the safety information on previous page.
2.Remove the control access cover.
3.Turn the valve control knob to the "OFF" position. To do this, you must turn the knob
clockwise to the "Pilot" position, and then press in and continue turning
clockwise to the "OFF" position.
GAS CONTROL VALVE
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
4.WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow "B" in the safety information on the previous page. If you don't smell gas, go to the next step.
5.The pilot should not require accessing for lighting purposes. The pilot is located at the left end of the burner.
PILOT ASSEMBLY
6.To put the control in the "Pilot" position, turn the
control knob
7.To light the pilot depress the control knob and then depress the red piezo button until it makes a clicking sound. It may be necessary to repeat this step. If the pilot does not light after 10 seconds, go back to step 3. The control knob should be held in for a MINUTE after pilot ignition.
•If the control knob does not pop out when re- leased,
•If the pilot will not stay lit after two tries, turn the control knob to the "OFF" position and call your service technician or gas supplier.
8.After the pilot has been lit, the burner can be turned
on by turning the knob
to the "ON" position. Flip the ON/OFF switch to the "ON" position.
9.Replace control access cover.
TO TURN OFF GAS APPLIANCE
1.Remove the control access cover.
2.Turn ON/OFF switch to "OFF".
3.Turn the valve control knob clockwise to the "Pilot" position, then depress knob and continue turning to "OFF" position.
4.Replace control access cover.
12