AVOID

_JJ

OCCURRENCE

Air conditioner cooling but

room too warrn-NO ice

forming on cooling coil

SERVICE

 

CHECKLIST

(continued)

{

 

 

POSSIBLE

CAUSE

 

SOLUTION

 

Front of unit

is blocked

by

Clear blockage

in front of unit.

drapes,

blinds, furniture,

etc,

 

 

Restricts

air

distribution_

 

 

 

behind decorative front. (continued)

Air conditioner turns on and off rapidly

Noise when air conditioner

operates on cooling,

Water dripping INSIDE

when air conditioner is cooling

Water dripping OUTSIDE

when air conditioner is cooling,

Air from unit does not feel

warm enough on Heat

setting (some models only),

Doors, windows, registers, etco

open -cold air escapes; hot air enters.

Unit recently turned on in hot room.

Insufficient cooling capacity.

Dirty air filter-air restricted°

Outside temperature

extremely hot.

Air sound.

Sound of fan hitting water-

moisture removal system.

Window vibrationo Poor installation.

Improper installation,

Unit removing large quantity of

moisture from humid room.

Selector switch in FAN or COOL position.

Thermostat set too cool

(higher number).

Room temperature Is warm enough,

Close doors, windows,

registers, etc

Allow additionaltime to remove

"stored heat" from walls, ceiling, floor and furniture.

Reconfirm the required cooling

capacity with your dealer.

clean air filter,

Set fan on high speed to bring

air past cooling coils more frequently,

Air sound is normal. If too loud,

turn selector switch to lower fan setting.

This is normal when humidity is high. Close doors, windows,

registers, etc

Refer to installation instruc-

tions.check with installer.

Tilt air conditioner slightly to the

outside to allow water

dralnage, Refer to installation

instructions-check with installer.

This is normal during

excessively humid days.

Turn switch counterclockwise to HEAT position.

Turn thermostat

counterclockwise to warmer

setting (lower numberL

Heating willnot occur until

temperature at the thermostat Is lower,

9

Image 9 Contents
Kenmore Automatic Air Conditioner Contents Installation Instructions Complete this adjustment before installing front panelInstalling Front to Unit Vent Control Starting Using Your NEW AIR ConditionerAIR Direction Super Thrust AIR ControlHOW to Lower Your Cooling Costs Cleaning and Replacing the AIR FilterAvoid Service Checklist Service Checklist Possible Cause Solution AvoidOccurrence OPEN/EXHAUST OccurrencepossiblecauseCleaning the Inside of Your AIR Conditioner Cleaning the Cabinet FrontRepairing Paint Damage Oiling of the FAN MotorKeep this Manual for Ready Reference NOW and Later KIT PartsPage Page Page Kenmore Automatic Air Conditioner WE Service What WE Sell